Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
June 2005
ISSN:
1437-4331
DOI:
10.1515/CCLM.2000.063

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Red Blood Cell Osmotic Fragility Confidence Intervals: a Definition by Application of a Mathematical Model

Alejandra Fernández-Alberti / Nilda E. Fink

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 38, Issue 5, Pages 433–436, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2000.063, June 2005

Publication History:
Published Online:
2005-06-01

Abstract

The red blood cell osmotic fragility test is based on the measure of the resistance of red blood cells to lysis as a function of decreasing NaCl concentration. Up to now, several methods have been used for recording these data, but for the first time, the human red blood cell osmotic fragility confidence interval using the Orcutt mathematical model was determined. The absorbance of the hemoglobin measured at 540 nm, released by the red blood cells of 40 healthy adult individuals, was fitted to the equation Absorbance=p3 erfc ([NaCl] − p1/p2); p3 measures one half the absorbance produced by maximum red blood cell hemolysis, p1 is the [NaCl] producing 50% red blood cell hemolysis, and p2 is the dispersion in [NaCl] producing red blood cell hemolysis. Confidence intervals (mean±SD) for the three parameters were as follows: p1=4.2718±0.1848; p2= 0.1947±0.0391, and p3=0.5568+0.0426. The usefulness of this osmotic fragility data analysis method using two pathological samples (β-thalassemia minor and hereditary spherocytosis) was demonstrated. Parameters of the fitted data were compared with those obtained by the conventional recording method of Beutler.

Comments (0)

Please log in or register to comment.