Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
May 2010
ISSN:
1437-4331
DOI:
10.1515/cclm.2010.227

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

A novel mutant-enriched liquidchip technology for the qualitative detection of somatic mutations in KRAS gene from both serum and tissue samples

Shiyang Wu1 / Zeyao Zhu1 / Jiaying He1 / Xiaodi Luo1 / Jiasen Xu1 / Lifen Ren-Heidenreich1

1SurExam Bio-Tech Co. Ltd., Guangzhou Technology Innovation Base, Science City, Guangzhou, P.R. China

Corresponding author: Lifen Ren-Heidenreich, SurExam Bio-Tech Co. Ltd., Guangzhou Technology Innovation Base, 80 Lan Yue Road, Science City, Guangzhou 510663, P.R. China

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 48, Issue 8, Pages 1103–1106, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/cclm.2010.227, May 2010

Publication History:
Received:
2009-08-24
Accepted:
2010-02-10
Published Online:
2010-05-19

Abstract

Background: Somatic mutations in the KRAS gene have been reported to confer drug resistance to epidermal growth factor receptor tyrosine kinase inhibitors and some monoclonal antibodies. However, current DNA mutation detection technologies are primarily DNA sequencing-based and not high throughput, nor sensitive enough to meet clinical needs.

Methods: A mutant-enriched PCR method was designed by introducing a unique restriction enzyme site to the PCR product. This allowed the wild-type KRAS sequence to be selectively removed by restriction enzyme digestion before application to the Luminex liquidchip system.

Results: A total of 100 copies of mutant KRAS DNA fragment mixed with 1×105 copies of the wild-type KRAS DNA could be detected to achieve a sensitivity of 0.1%. This technology is currently used for clinical testing of KRAS somatic mutations for the purpose of pharmacogenomic evaluation. Serum samples from 109 patients with non-small cell lung cancer were tested and 34 mutations were detected (34/109). The formalin-fixed and paraffin-embedded samples from 60 patients with colorectal cancer were tested and 19 mutations were detected (19/60).

Conclusions: A novel, qualitative, sensitive, reliable and high throughput liquidchip technology has been developed for detecting KRAS mutations using clinical serum and formalin-fixed and paraffin-embedded samples.

Clin Chem Lab Med 2010;48:1103–6.

Keywords: KRAS; liquidchip; mutant-enriched PCR; somatic mutations

Comments (0)

Please log in or register to comment.