Jump to ContentJump to Main Navigation

Online

99,00 € / $149.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
October 2006
ISSN:
1862-278X
DOI:
10.1515/BMT.2006.036

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 99.00
RRP for USA, Canada, Mexico
US$ 149.00 *
Print
Individual Subscription Online only
Euro [D] 506.00
RRP for USA, Canada, Mexico
US$ 759.00 *
Print + Online
Individual Subscription Online only
Euro [D] 608.00
RRP for USA, Canada, Mexico
US$ 911.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Editor-in-Chief: Dössel, Olaf

Editorial Board Member: Augat, Peter / Bösiger, Peter / Gehring, Hartmut / Haueisen, Jens / Leonhardt, Steffen / Niederlag, Wolfgang / Radermacher, Klaus M. / Schmitz, Georg / Witte, Herbert / Boenick, Ulrich / Lenthe, Harry / Penzel, Thomas / Clasbrummel, Bernhard / Robitzki, Andrea A. / Scholz, Jörg / Snedeker, Jess G. / Wintermantel, Erich / Jockenhoevel, Stefan / Gilly, Hermann / Werner, Jürgen / Plank, Gernot / Stieglitz, Thomas

6 Issues per year

Increased IMPACT FACTOR 2011: 0.855
5-year IMPACT FACTOR: 0.745
Rank 56 out of 72 in category Biomedical Engineering and rank 20 out of 23 in category Medical Informatics in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Spatiotemporal correlation analyses: a new procedure for standardisation of DC magnetocardiograms

Matthias Goernig1 / Christian Tute2 / Mario Liehr3 / Stephan Lau4 / Jens Haueisen5 / Hans R. Figulla6 / Uwe Leder7

1.

2.

3.

4.

5.

6.

7.

Corresponding author: Matthias Görnig, Department of Internal Medicine I, Friedrich Schiller University Jena, Erlanger Allee 101, 07747 Jena, Germany Phone: +49-3641-9324101 Fax: +49-3641-9324102

Citation Information: Biomedizinische Technik. Volume 51, Issue 4, Pages 198–200, ISSN (Online) 1862-278X, ISSN (Print) 0013-5585, DOI: 10.1515/BMT.2006.036, October 2006

Publication History:
Published Online:
2006-10-25

Abstract

There is a lack of standard methods for the analysis of magnetocardiograms (MCGs). MCG signals have a shape similar to the ECG (P wave, QRS complex, T wave). High-quality multichannel recordings can indicate even slight disturbances of de- and repolarisation. The purpose of our study was to apply a new approach in the analysis of signal-averaged DC-MCGs. DC-MCGs (31-channel) were recorded in 182 subjects: 110 patients after myocardial infarction and 72 controls. Spatiotemporal correlation analysis of the QRS complex and T wave patterns throughout the entire heart cycle was used to analyse homogeneity of de- and repolarisation. These plots were compared to standard ECG analyses (electrical axis, Q wave, ST deviation, T polarity and shape). Spatiotemporal correlation analyses seem to be applicable in assessing the course of electrical repolarisation with respect to homogeneity. MCG provided all diagnostic information contained in common ECG recordings at high significance levels. The ECG patterns were included in 5/8 of our parameters for electrical axis, 6/8 for Q-wave, 7/8 for ST deviation and 5/8 for T-polarity based on two time series of correlation coefficients. We conclude that our spatiotemporal correlation approach provides a new tool for standardised analysis of cardiac mapping data such as MCG.

Keywords: electrocardiography; magnetocardiography; myocardial infarction; repolarization; spatiotemporal analyses

Comments (0)

Please log in or register to comment.