Jump to ContentJump to Main Navigation

Online

99,00 € / $149.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
February 2007
ISSN:
1862-278X
DOI:
10.1515/BMT.2007.006

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 99.00
RRP for USA, Canada, Mexico
US$ 149.00 *
Print
Individual Subscription Online only
Euro [D] 506.00
RRP for USA, Canada, Mexico
US$ 759.00 *
Print + Online
Individual Subscription Online only
Euro [D] 608.00
RRP for USA, Canada, Mexico
US$ 911.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Editor-in-Chief: Dössel, Olaf

Editorial Board Member: Augat, Peter / Bösiger, Peter / Gehring, Hartmut / Haueisen, Jens / Leonhardt, Steffen / Niederlag, Wolfgang / Radermacher, Klaus M. / Schmitz, Georg / Witte, Herbert / Boenick, Ulrich / Lenthe, Harry / Penzel, Thomas / Clasbrummel, Bernhard / Robitzki, Andrea A. / Scholz, Jörg / Snedeker, Jess G. / Wintermantel, Erich / Jockenhoevel, Stefan / Gilly, Hermann / Werner, Jürgen / Plank, Gernot / Stieglitz, Thomas

6 Issues per year

Increased IMPACT FACTOR 2011: 0.855
5-year IMPACT FACTOR: 0.745
Rank 56 out of 72 in category Biomedical Engineering and rank 20 out of 23 in category Medical Informatics in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Implantable cardioverter defibrillator algorithms: status review in terms of computational cost

Antonio Cebrián1 / José Millet2 / Francisco Castells3

1.

2.

3.

Corresponding author: Antonio Cebrián, Universidad Politécnica de Valencia, Departemento de Ingeniería Electrónica, Camino de Vera s/n, 46022 Valencia, Spain Phone: +34-96-3877605 Fax: +34-96-3879609

Citation Information: Biomedizinische Technik. Volume 52, Issue 1, Pages 25–30, ISSN (Online) 1862-278X, ISSN (Print) 0013-5585, DOI: 10.1515/BMT.2007.006, February 2007

Publication History:
Published Online:
2007-02-22

Abstract

In recent decades, implantable cardioverter defibrillators (ICDs) have improved substantially, becoming the treatment of choice for patients at high risk of life-threatening arrhythmias. Nevertheless, inappropriate shock therapy for non-ventricular arrhythmias is still a problem. Extending the ICD battery lifetime demands very low power consumption, which is obtained at very low microprocessor clock frequencies. Currently, some high-performance algorithms remain beyond the computational capabilities of ICDs. Future ICDs with higher computing power will permit the implementation of computationally intensive algorithms, enhancing the discrimination performance and preventing inappropriate shock therapies. An ICD algorithm status review is presented from the point of view of signal processing techniques and their computational costs. Several examples of discrimination algorithms with increasing computational cost are analyzed. Whereas some of them are already used in commercial ICDs, other algorithms cannot be implemented yet in current ICDs. A solution based on dynamic adaptation of microprocessor power consumption to meet algorithm computational requirements is proposed. This solution allows implementation of complex discrimination algorithms in ICDs without significantly increasing the power consumption.