Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
June 2005
ISSN:
1437-4331
DOI:
10.1515/CCLM.1998.138

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Normalizing Intermethod Free Triiodothyronine Patient Results: Need for Commutable Materials

Giampaolo Cattozzo / Giorgio Scarsi / Carlo Franzini

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 36, Issue 10, Pages 777–780, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.1998.138, June 2005

Publication History:
Published Online:
2005-06-01

Abstract

The aim of this work was to check the suitability of control materials to normalize intermethod results for the measurement of free triiodothyronine in patient sera. In the main experiment, 108 patient sera and 11 commercially available control materials were assayed by a pair of methods. In a confirmatory experiment, two of the control materials and 142 patient sera were assayed with an alternative pair of methods. In the main experiment, the intermethod variability of 6/11 control materials differed significantly from that of patient sera (i. e. control materials were non-commutable). Recalculation of patient results using control materials as calibrators lowered the intermethod difference only if commutable materials were used. The confirmatory experiment demonstrated that the pattern of commutability changed if a different pair of methods was used. We conclude that in the case of free triiodothyronine the commutability of control materials should be tested if they are to be used to normalize patient results obtained by different methods.