Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Validation of an Automated Enzyme Immunoassay for Interleukin-6 for Routine Clinical Use

Peter Fraunberger / Matthias Pfeiffer / Peter Cremer / Ernst Holler / Dorothea Nagel / Isabelle Dehart / Michael Thein / Autar K. Walli / Dietrich Seidel

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 36, Issue 10, Pages 797–801, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.1998.141, June 2005

Publication History:
Published Online:
2005-06-01

Abstract

Serum levels of Interleukin-6 (IL-6), a proinflammatory cytokine, are increased in early stages of inflammatory diseases such as infection and sepsis. Assay systems which permit its measurement within a few hours and as a single measurement have not been reported so far. We therefore evaluated a now commercially available automated method for IL-6 measurement on the Cobas Core® immunological analyzer (Roche Diagnostic Systems) which enables single IL-6 measurement within about 1 hour. The automated assay correlates well with an established, manual microtiter plate assay (Biosource GmbH) which uses the same antibodies and reagents (r=0.98). Accuracy of the automated method was established by adding known amounts of IL-6 international reference preparation. Recovery of the international standard was in the range of 92–104 %. The automated assay had a precision of singletons below 6% and was linear up to 2800 pg/ml. This automated assay provides a suitable, convenient and time saving method for measurement of IL-6 serum levels in the routine clinical laboratory.