Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
June 2005
ISSN:
1437-4331
DOI:
10.1515/CCLM.1999.113

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Identification of IgG-specific Oligoclonal Banding in Serum and Cerebrospinal Fluid by Isoelectric Focusing: Description of a Simplified Method for the Diagnosis of Neurological Disorders

P. Marchetti / J. Gutierrez / P. Velia / J.-L. Faucompré / B. Onraed / P. Formstecher / B. Hennache

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 37, Issue 7, Pages 735–738, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.1999.113, June 2005

Publication History:
Published Online:
2005-06-01

Abstract

Clinical laboratory procedures using cerebrospinal fluid (CSF) to assist in the diagnosis of multiple sclerosis (MS) are based essentially on the determination of oligoclonal bands (OB) in CSF and not in serum. To date, the techniques using isoelectric focusing (IEF) have represented one of the most efficient methods for detecting supernumerary bands in CSF but unfortunately were not always compatible with a routine use. Here, we describe a revised method of IEF suitable for the diagnosis of neurological disorders. The kit-based technique was simplified and the present procedure allowed an easier execution, reduced the overall analysis time and permitted an uncomplicated intepretation of oligoclonal profiles. Moreover, the technique developed was very sensitive and specific for the diagnosis of MS diagnosis. In conclusion, the IEF protocol described in this report is suitable for OB detection in any laboratory.

Comments (0)

Please log in or register to comment.