Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
June 2005
ISSN:
1437-4331
DOI:
10.1515/CCLM.2000.153

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Evaluation of Two Automated Enzyme Immunoassays for Detection of Antinuclear Antibodies

Xavier Bossuyt

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 38, Issue 10, Pages 1033–1037, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2000.153, June 2005

Publication History:
Published Online:
2005-06-01

Abstract

We evaluated two enzyme immunoassays (EIA) for detection of antinuclear antibodies (ANA) which became recently available and which were designed for application on a fully automated system; (i) the EIA-ANA screen kit from Sigma Diagnostics (St. Louis, MO, USA) applied on APTUS™, an automated EIA analyser from Sigma Diagnostics and (ii) the Cobas® Core Hep-2 EIA-ANA assay applied on the fully automated Cobas Core immunochemistry analyzer from Roche Diagnostics (Basel, Switzerland). The evaluation was done by an analytic comparison of the automated systems to an established indirect immunofluorescence (IF) method performed on SSA transfected human epitheloid cell substrate slides. Three hundred and thirty six samples were tested with the Sigma EIA-ANA assay and 603 samples with the Cobas® Core Hep-2 EIA-ANA assay. For both EIA systems, there was a trend of generally increasing signal from the assay system with increasing IF-ANA titers. With an IF-ANA reference range of < 1:160, concordance between Sigma® EIA-ANA and IFANA was 86% and concordance between Roche® EIA-ANA and IF-ANA was 85%. When compared to IF-ANA with a reference range of < 1:160, sensitivity and specificity of the EIA-ANA screen was 0.65 and 0.92, respectively, for Sigma® EIA-ANA and 0.61 and 0.91, respectively, for the Cobas® Core assay. The low sensitivity observed with both methods is a major concern. Sigma EIA-ANA screen revealed the presence of autoantibodies in 23 of the 29 samples containing antibodies to extractable nuclear antigens (ENA) and/or double stranded DNA and the Cobas® Core Hep-2 EIA-ANA assay revealed the presence of autoantibodies in 40 of the 43 samples containing antibodies to ENA and/or double stranded DNA.

Comments (0)

Please log in or register to comment.