Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
June 2005
ISSN:
1437-4331
DOI:
10.1515/CCLM.2000.163

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Comparison of Proteolytic Enzymes and Glutathione S-Transferase Levels in Non-Heart-Beating Donors' (NHBD) Kidney Perfusates

Shlokarth Balupuri / David Talbot / Mohamed El-Sheikh / Chris Snowden / Derek M. Manas / John Kirby / David Mantle

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 38, Issue 11, Pages 1099–1102, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2000.163, June 2005

Publication History:
Published Online:
2005-06-01

Abstract

In order to identify biochemical markers of kidney damage prior to transplantation, we determined the levels of activity of a range of proteolytic enzymes in kidney perfusate samples from non-heart-beating donor (NHBD) cases. Urinary protease activities have been described as indices of kidney damage in renal disease; their potential as markers of tissue damage in kidneys before transplantation has not been assessed. In an attempt to identify additional/ improved biochemical markers, the present study compared the levels of total glutathione S-transferase (GST) with corresponding levels of several proteolytic enzymes in perfusate fluid from machine perfused NHBD kidneys. Proteases were selected to represent factors that may influence enzyme efflux, such as intracellular localization or molecular size.

Methods: Perfusate samples were obtained over an 8-hour period from machine-preserved NHBD kidneys. Protease activities in these samples were determined by fluorometric assays and comparison made with total GST activity. Individual proteases were analysed in the transplanted and non-transplanted kidney groups (discarded on the basis of other viability parameters).

Results: A correlation between protease activity and total GST was obtained for only leucyl- and pyroglutamyl aminopeptidase. Furthermore, in the transplanted group, it was possible to set nominal upper limits of activity for alanyl-arginyl- and dipeptidyl IV-aminopeptidase (AP). In the non-transplanted kidney group protease levels were increased above “normal” upper limits for the same enzyme types. By the use of alanyl AP it was possible to discriminate 75% of unsuitable kidneys discarded by the use of other criteria.

Conclusion: The lack of correlation between total GST and protease activity for most of the enzymes investigated and alanyl AP levels in perfusate samples could be related to differences in cellular localisation, suggesting that assays of alanyl AP may give complimentary biochemical information relating to kidney tissue damage. Quantification of alanyl AP in machine perfusate samples may be a valuable additional independent biomarker of tissue damage.

Comments (0)

Please log in or register to comment.