Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
November 2000
ISSN:
1437-4331
DOI:
10.1515/CCLM.2000.189

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Comparison of Five Cyclosporin Immunoassays with HPLC

J. Michael Tredger / Norman Roberts / Roy Sherwood / Gerald Higgins / Jim Keating

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 38, Issue 11, Pages 1205–1207, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2000.189, November 2000

Abstract

High performance liquid chromatography (HPLC) is the reference method for cyclosporin (CyA) measurements but therapeutic monitoring of the drug is frequently made using the more practical immunoassays. Cross-reactivity with CyA metabolites may compromise the specificity of immunoassays, particularly in liver graft recipients where metabolites may accumulate. The aim of this study was to compare with HPLC the performance of two recently introduced CyA immunoassays (the AxSYM fluorescent polarisation immunoassay (FPIA) and non-extraction CEDIA assay). The comparison was extended to the well-established TDx monoclonal FPIA (TDx mono) and the enzyme multiplied (EMIT)-specific assays and to the polyclonal FPIA (TDx poly), in which metabolite cross-reactivity is extensive. Assays were performed on 106 blood samples (taken 6 days to 118 months post-liver transplant) and results were compared by non-parametric regression analysis and difference plots. AxSYM and CEDIA showed both constant and proportional bias against HPLC (unlike EMIT) but the mean difference from HPLC was least for AxSYM (2.7 μg/l vs. 11.7, 9.4 and 54 μg/l for CEDIA, EMIT and TDx mono, respectively. (TDx poly – HPLC) values were proportional to all immunoassay results, with slopes of 0.33, 0.38 and 0.45 for EMIT, AxSYM and CEDIA, respectively. Our data suggest close agreement between AxSYM, CEDIA and EMIT results.

Comments (0)

Please log in or register to comment.