Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
June 2005
ISSN:
1437-4331
DOI:
10.1515/CCLM.2000.047

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Comparison of the Abbott IMx® and a High-Performance Liquid Chromatography Method for Measuring Total Plasma Homocysteine

Francisco Blanco-Vaca / Rosa Arcelús / Francesc González-Sastre / Jordi Ordóñez-Llanos / Josep M. Queraltó-Compañó

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 38, Issue 4, Pages 327–329, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2000.047, June 2005

Publication History:
Published Online:
2005-06-01

Abstract

The determination of the total concentration of plasma homocysteine is of interest in a variety of clinical circumstances, especially, in the evaluation of the risk of cardiovascular disease. However, most of the methods available to date, many of them chromatographic, are not well suited for the majority of clinical laboratories. Several automated methods are now or will be, shortly, commercially available. We have compared one of them, the fluorescence polarization immunoassay (FPIA) adapted to the IMx® analyzer (Abbott Laboratories), with the high-performance liquid chromatography (HPLC) method with fluorescent detection currently used in our laboratory. The results show that the FPIA-IMx® method is less imprecise and slightly more sensitive than the HPLC. The comparison of 67 clinical plasma specimens indicated that there is a proportional error disagreement between FPIA-IMx® and HPLC (FPIA=1.19 HPLC + 0.92; confidence region for slope and y-intercept were, respectively, from 1.06 to 1.31 and from−0.06 to 2.32). The nature of this error is not explained by the experiments performed to study the inaccuracy of both methods, which included the investigation of dilution parallelism, analytical recovery and cross-reactivity. The different results of homocysteine concentration obtained with FPIA-IMx® and HPLC must be taken into account when a change of methodology is under consideration.

Comments (0)

Please log in or register to comment.