Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
June 2005
ISSN:
1437-4331
DOI:
10.1515/CCLM.2002.064

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Comparison of Quick and Owren Prothrombin Time with Regard to the Harmonisation of the International Normalised Ratio (INR) System

Juha Horsti

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 40, Issue 4, Pages 399–403, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2002.064, June 2005

Publication History:
Published Online:
2005-06-01

Abstract

Prothrombin time (PT) is tested mostly to monitor patients on oral anticoagulant treatment. The International Normalised Ratio (INR) was introduced to improve and harmonise PT results and therapeutic range globally for patient care and the scientific literature.

We studied the Quick PT in 179 patients and the Owren PT in 137 patients on oral anticoagulant therapy using two different reagents for the two methods of measuring PT. We assessed the clinical significance of the INR results obtained by each method using the two reagents and compared the Quick and Owren methods.

We conclude that with the Quick method individual INR results differed from each other too much clinically, while using the Owren method individual INR results were clinically acceptable. Our opinion is that we should develop the INR system using the Owren PT method rather than the Quick to improve patient care.

Comments (0)

Please log in or register to comment.