Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
June 2005
ISSN:
1437-4331
DOI:
10.1515/CCLM.2002.102

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Comparison of Laser-Probe and Photometric Determination of the Urinary Crystallization Risk of Calcium Oxalate

Norbert Laube / Stefan Hergarten / Albrecht Hesse

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 40, Issue 6, Pages 595–599, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2002.102, June 2005

Publication History:
Published Online:
2005-06-01

Abstract

A variety of equipment is used for the observation of precipitation processes which occur in urinary samples. The Bonn-Risk-Index, a measure of the calcium oxalate crystallization risk of human urine, has been developed with the use of an in-line laser-probe gauge. For basic research or in clinical laboratories, however, this instrument, which fulfills industrial requirements for the evaluation of particle size distributions, is not widely available. The evaluation of an alternative method to determine the Bonn-Risk-Index based on a more commonly available apparatus would therefore be useful.

In vitro crystallization experiments with 124 native urine samples from stone-forming and non-stone forming individuals were performed in order to determine their crystallization risk according to the Bonn-Risk-Index approach. The onset of an induced urinary crystallization was detected by simultaneous sample monitoring with an in-line laser-probe and a conventional dip-in photometer. A decrease of the sample's relative light transmissivity from initially 100% to 98% was assumed to be a reliable photometer-based criterion to indicate that crystallization actually began. The laser-probe signal was set as the reference measure.

Linear regression analysis of the results of the laser-probe and the photometer-based Bonn-Risk-Index determinations reveals a significant and close correlation between the two measures. Method comparison by statistical evaluation shows i) that no significant deviation from linearity exists and ii) that both methods are statistically identical. The differences in the results are small enough to be confident that the photometer can be used in place of the laser-probe for clinical purposes.

The photometer is a reliable, easy-to-use and cost-effective method for the determination of a triggered crystallization event in a urine sample. The assumed 98% criterion allows the determination of the Bonn-Risk-Index with adequate accuracy.

Comments (0)

Please log in or register to comment.