Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
June 2005
ISSN:
1437-4331
DOI:
10.1515/CCLM.2002.108

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Evaluation of Commutability of Control Materials

Emmanuel Brion / Jean-Marc Lessinger / Nicholas Gould / Jacky Leyendecker / Georges Férard

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 40, Issue 6, Pages 625–630, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2002.108, June 2005

Publication History:
Published Online:
2005-06-01

Abstract

The commutability of 13 control materials was evaluated by performing parallel measurements on two different analysers: a Synchron CX-5 Delta from Beckman-Coulter and a Vitros 950 from Ortho-Clinical Diagnostics. Twenty three clinical chemistry analytes (substrates, electrolytes and enzymatic activities) were determined in plasma from 15 different patients in order to define intermethod relationship for each analyte. The relationship observed for each control material was compared to those obtained for patients' specimens. The results show that commutability depends both on the tested analyte and on the control material. No totally commutable material has been found for the whole set of tested parameters. Most control materials were commutable for inorganic phosphate, glucose, chloride, triglycerides, alanine aminotransferase, amylase and γ-glutamyltransferase, but less than a quarter of control materials were commutable for sodium, calcium, creatinine, alkaline phosphatase and lipase. Seven materials were commutable for more than half of the analytes, whereas five control materials were commutable for less than a quarter of these analytes. We propose to verify the commutability of materials before their use in an external quality control assessement.

Comments (0)

Please log in or register to comment.