Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
June 2005
ISSN:
1437-4331
DOI:
10.1515/CCLM.2002.146

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Evaluation of Denka-Seiken Turbidimetric High-Sensitivity C-Reactive Protein Assay

Hyun Ju Sung / Jeong-Ho Kim / Rojin Park / Kyung Ryul Lee / Oh Hun Kwon

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 40, Issue 8, Pages 840–845, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2002.146, June 2005

Publication History:
Published Online:
2005-06-01

Abstract

C-reactive protein measured with a high sensitivity method (hsCRP) is an important prognostic indicator in patients with an acute coronary syndrome. We evaluated hsCRP measurement with regard to its precision, functional sensitivity, linearity, and interferences using Denka-Seiken CRP II Latex X2 turbidimetric method on two chemistry autoanalyzers: Olympus AU 640 and Hitachi 747. The coefficients of variation (CV) for within-run and between-run precision of hsCRP were satisfactory on both autoanalyzers. Functional sensitivities, expressed as concentrations associated with 10% total interassay CV, were 0.19 mg/l for the Hitachi 747 analyzer and 0.41 mg/l for the Olympus AU 640. The assay was linear up to 300 mg/l with a wide measuring range, which suggested the possibility of using this hsCRP measurement as an inflammation marker and as a risk marker for coronary heart disease (CHD). No significant interference was observed up to a triglyceride concentration of 34 mmol/l, and up to hemoglobin concentration of 4 g/l. The determination of hsCRP by turbidimetric method was satisfactory and acceptable for CHD risk assessment, as well as for use as a marker of inflammation.

Comments (0)

Please log in or register to comment.