Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
June 2005
ISSN:
1437-4331
DOI:
10.1515/CCLM.2003.242

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Profiling and in vivo Quantification of Proteins by High Resolution Mass Spectrometry: The Example of Goserelin, an Analogue of Luteinizing Hormone-Releasing Hormone

Sophie Michalet / Philippe Favreau / Reto Stöcklin

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 41, Issue 12, Pages 1589–1598, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2003.242, June 2005

Publication History:
Published Online:
2005-06-01

Abstract

Proteins are essential biomolecules which are frequently involved in major pathological syndromes and are widely used as diagnostic markers or therapeutic agents. The emergence of proteomics will doubtless further increase the significance of proteins both in the clinic and in the life sciences in general. Our main objective is to offer innovative solutions to what we like to call the “post-proteomics era”. To achieve our goal, we intend to develop novel approaches and technologies for in vivo metabolic studies of proteins using mass spectrometry (MS), focusing on pharmacokinetics and pharmacodynamics. Using goserelin as a model, we have successfully developed and validated a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection and quantification of an intact analogue of luteinizing hormone-releasing hormone (LHRH) in small volumes of rat plasma samples at concentrations ranging from 0.3 to 405.0 μg/l. To this end, a microbore reversed-phase-HPLC system was coupled on-line to a tandem high resolution quadrupole time-of-flight (Q-TOF) instrument fitted with an electrospray ion source and operated in LC-MS/MS mode. External calibration was used and the high resolution was crucial to discard contaminating signals, which would not have been possible with the more conventional triple quadrupole mass spectrometers operated in a static mode. For low sample amounts, calibration curves were constructed corresponding to rat plasma levels of 0.3 to 16.4 μg/l and found to be of third order with a coefficient of determination greater than 0.999. The relative standard deviation was found to be lower than 15%. A lower limit of detection (LLOD) of 0.17 μg/l and a lower limit of quantification (LLOQ) of 0.3 μg/l were determined.

Comments (0)

Please log in or register to comment.