Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
June 2005
ISSN:
1437-4331
DOI:
10.1515/CCLM.2003.188

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Biological Variability of Albumin Excretion Rate and Albumin-to-Creatinine Ratio in Hypertensive Type 2 Diabetic Patients

Andrea Mosca / Renata Paleari / Ferruccio Ceriotti / Annunziata Lapolla / Domenico Fedele

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 41, Issue 9, Pages 1229–1233, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2003.188, June 2005

Publication History:
Published Online:
2005-06-01

Abstract

The importance of measuring microalbuminuria is well established. However, only scanty data are available concerning the biological variability of albumin excretion in type 2 diabetic subjects. We report our experience from a large clinical trial of a new antihypertensive drug (Lercanidipine) designed to reduce albumin excretion and blood pressure in type 2 diabetic patients with hypertension and microalbuminuria.

Eighty seven patients with persistent microalbuminuria were studied within 1 year of the clinical trial. The measurements were performed on blood and timed urine samples frozen at −80 °C and shipped to a central laboratory unit. Preliminary experiments were performed to assess albumin stability in urine under various conditions (4 °C, −20 °C and −80 °C), particularly with regard to the albumin/creatinine ratio. Urine samples can be stored up to 3 weeks at 4 °C or up to 2 months at −80 °C. The biological variability of the albumin excretion rate was 25.7%, while that of the albumin/creatinine ratio was 13.4%. These data are useful in defining the analytical goals of imprecision for microalbuminuria (CV = 13% for albumin, and CV = 6% for albumin/creatinine ratio). No correlation between albumin/creatinine ratio and HbA1c was found in the cohort of 61 microalbuminuric patients who completed the trial.

The results of this study confirm that the albumin/creatinine ratio is much more suitable for monitoring albumin excretion in longitudinal studies than the albumin excretion rate.

Comments (0)

Please log in or register to comment.