Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
September 2004
ISSN:
1437-4331
DOI:
10.1515/CCLM.2004.213

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Diagnostic efficiency of different amphetamine screening tests – the search for an optimal cutoff

Reto Savoca1 / Katharina M. Rentsch2 / Andreas R. Huber3

1.

2.

3.

Corresponding author: Reto Savoca, PhD, Center of Laboratory Medicine, Kantonsspital Aarau, 5001 Aarau, Switzerland. Phone: +41-62-838-54-63, Fax: +41-62-838-53-99, E-mail:

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 42, Issue 9, Pages 1063–1065, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2004.213, September 2004

Publication History:
Received:
March 8, 2004
Accepted:
June 28, 2004

Abstract

Increased use of designer drugs (amphetamines and amphetamine-like substances) raises the need for fast screening tests in urine in clinical settings, workplace and drug rehabilitation. Immunological assays currently used are subject to unwanted crossreactivities, partly depending on the cutoff concentrations used. The values recommended in Europe and the USA are 500 and 1000 ng/ml, respectively. In Switzerland, the recommended concentration of 300 ng/ml results in a high rate of false-positive urine samples and expensive, time-consuming confirmation testing. Using the Abbott Axsym analyzer, we found numerous false positives from patients in rehabilitation centers due to concomitant medication. Therefore, the diagnostic sensitivity and specificity of the Abbott test at different cutoff concentrations and the sensitivity of the Roche Cobas Integra, Beckman Synchron and Biosite Triage point-of-care test were examined. HPLC Bio-Rad Remedi was chosen as the method of higher hierarchical order. The specificity of the Axsym analyzer (300 ng/ml) was 86%. At 500 ng/ml or 1000 ng/ml the specificity was increased to 99 or 100%, respectively, while the sensitivity only decreased from 97 to 91 or 81%, respectively. In summary, the cutoff concentration for amphetamine screening tests should not be below 500 ng/ml to avoid a high rate of false-positive results.

Keywords: amphetamine; Axsym; cutoff; HPLC; screening test

Comments (0)

Please log in or register to comment.