Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
August 2005
ISSN:
1437-4331
DOI:
10.1515/CCLM.2005.145

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Reference materials (RMs) for analysis of the human factor II (prothrombin) gene G20210A mutation

Christoph L. Klein1 / János Márki-Zay2 / Philippe Corbisier3 / David Gancberg4 / Susan Cooper5 / Donato Gemmati6 / Walter-Michael Halbmayer7 / Steve Kitchen8 / Béla Melegh9 / Michael Neumaier10 / Johannes Oldenburg11 / Elisabeth Oppliger Leibundgut12 / Pieter H. Reitsma13 / Sandra Rieger14 / Heinz G. Schimmel15 / Michael Spannagl16 / Attilia Tordai17 / Alberto Tosetto18 / Sophie Visvikis19 / Renata Zadro20 / Christine Mannhalter21

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

Corresponding author: Christoph L. Klein, European Commission, Joint Research Centre, Institute for Reference Materials and Measurements, Retieseweg 111, 2440 Geel, Belgium Phone: +32-14-571634, Fax: +32-14-571548,

Citation Information: Clinical Chemical Laboratory Medicine. Volume 43, Issue 8, Pages 862–868, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2005.145, August 2005

Publication History:
Received:
March 7, 2005
Accepted:
June 17, 2005

Abstract

The Scientific Committee of Molecular Biology Techniques (C-MBT) in Clinical Chemistry of the IFCC has initiated a joint project in co-operation with the European Commission, Joint Research Centre, Institute of Reference Materials and Measurements to develop and produce plasmid-type reference materials (RMs) for the analysis of the human prothrombin gene G20210A mutation. Although DNA tests have a high impact on clinical decision-making and the number of tests performed in diagnostic laboratories is high, issues of quality and quality assurance exist, and currently only a few RMs for clinical genetic testing are available. A gene fragment chosen was produced that spans all primer annealing sites published to date. Both the wild-type and mutant alleles of this gene fragment were cloned into a pUC18 plasmid and two plasmid RMs were produced. In addition, a mixture of both plasmids was produced to mimic the heterozygous genotype. The present study describes the performance of these reference materials in a commutability study, in which they were tested by nine different methods in 13 expert laboratories. This series of plasmid RMs are, to the best of our knowledge, the first plasmid-type clinical genetic RMs introduced worldwide.

Keywords: metrological traceability; molecular diagnostic testing; mutation; polymerase chain reaction; prothrombin; recombinant DNA; reference standards

Comments (0)

Please log in or register to comment.