Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
August 2005
ISSN:
1437-4331
DOI:
10.1515/CCLM.2005.147

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Educational intervention together with an on-line quality control program achieve recommended analytical goals for bedside blood glucose monitoring in a 1200-bed university hospital

Víctor Sánchez-Margalet1 / Manuel Rodriguez-Oliva2 / Cristina Sánchez-Pozo3 / María Francisca Fernández-Gallardo4 / Raimundo Goberna5

1.

2.

3.

4.

5.

Corresponding author: Raimundo Goberna, Department of Clinical Chemistry, Virgen Macarena University Hospital, Av. Dr. Fedriani 3, Seville 41071, Spain Phone: +34-955008104, Fax: +34-955008105,

Citation Information: Clinical Chemical Laboratory Medicine. Volume 43, Issue 8, Pages 876–879, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2005.147, August 2005

Publication History:
Received:
April 5, 2005
Accepted:
June 17, 2005

Abstract

Portable meters for blood glucose concentrations are used at the patients bedside, as well as by patients for self-monitoring of blood glucose. Even though most devices have important technological advances that decrease operator error, the analytical goals proposed for the performance of glucose meters have been recently changed by the American Diabetes Association (ADA) to reach <5% analytical error and <7.9% total error. We studied 80 meters throughout the Virgen Macarena Hospital and we found most devices with performance error higher than 10%. The aim of the present study was to establish a new system to control portable glucose meters together with an educational program for nurses in a 1200-bed University Hospital to achieve recommended analytical goals, so that we could improve the quality of diabetes care. We used portable glucose meters connected on-line to the laboratory after an educational program for nurses with responsibilities in point-of-care testing. We evaluated the system by assessing total error of the glucometers using high- and low-level glucose control solutions. In a period of 6 months, we collected data from 5642 control samples obtained by 14 devices (Precision PCx) directly from the control program (QC manager). The average total error for the low-level glucose control (2.77 mmol/l) was 6.3% (range 5.5–7.6%), and even lower for the high-level glucose control (16.66 mmol/l), at 4.8% (range 4.1–6.5%). In conclusion, the performance of glucose meters used in our University Hospital with more than 1000 beds not only improved after the intervention, but the meters achieved the analytical goals of the suggested ADA/National Academy of Clinical Biochemistry criteria for total error (<7.9% in the range 2.77–16.66 mmol/l glucose) and optimal total error for high glucose concentrations of <5%, which will improve the quality of care of our patients.

Keywords: educational intervention; glucose meter; glucose monitoring; on-line quality control; point-of-care testing