Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
January 2006
ISSN:
1437-4331
DOI:
10.1515/CCLM.2006.015

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Quantitative bacterial micro-assay for rapid detection of serum phenylalanine on dry blood-spots: application in phenylketonuria screening

Sadeq Vallian1 / Hassan Moeini2

1.

2.

Corresponding author: Sadeq Vallian, PhD, Associate Professor of Medical Genetics, Division of Genetics, Department of Biology, Faculty of Science, Isfahan University, Hezarjerib St., Isfahan, Iran Phone/Fax: +98-311-7932456,

Citation Information: Clinical Chemical Laboratory Medicine. Volume 44, Issue 1, Pages 76–79, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2006.015, January 2006

Publication History:
Received:
August 26, 2005
Accepted:
October 18, 2005

Abstract

Phenylketonuria is an inherited metabolic disease, which is characterized by an increased level of serum phenylalanine. Quantitative measurement of phenylalanine in the serum of phenylketonuria patients is necessary to confirm the disease, and to distinguish phenylketonuria from other forms of hyperphenylalaninemia. In this study, we report a rapid and inexpensive micro-assay for simultaneous detection and quantitative measurement of serum phenylalanine on dry blood-spots. Analysis of the standard curve showed a broad linear range for phenylalanine from 120 to 1800 μmol/L. Application of this method, the standard Guthrie bacterial inhibition assay and a high-performance liquid chromatography (HPLC) method for analysis of 34 samples from phenylketonuria patients and control samples produced comparable results, with the regression equation Y=0.994X+0.996. The advantage of this method over the Guthrie bacterial inhibition assay is its ability to measure serum phenylalanine quantitatively without false positive results. The method was successfully applied to dried blood-spots, serum and whole blood. The cost per sample is approximately 20–50 US cents, which is much less than for HPLC and commercial enzyme kits. The method can be automated, and is thus suitable for neonatal and mass screening for phenylketonuria, especially in developing countries where funding is a limiting factor.

Keywords: Guthrie; phenylalanine; phenylketonuria; screening

Comments (0)

Please log in or register to comment.