Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
January 2006
ISSN:
1437-4331
DOI:
10.1515/CCLM.2006.020

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Analytical performance of a new two-step ADVIA Centaur® estradiol immunoassay during ovarian stimulation

Catherine Massart1 / Jacqueline Gibassier2 / Marie-Christine Laurent3 / Dominique Le Lannou4

1.

2.

3.

4.

Corresponding author: Catherine Massart, Laboratoire de Génétique Moléculaire et Hormonologie, CHU de Pontchaillou, rue Le Guilloux, 35043 Rennes, France Fax: +33-299-284-145,

Citation Information: Clinical Chemical Laboratory Medicine. Volume 44, Issue 1, Pages 105–109, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2006.020, January 2006

Publication History:
Received:
August 18, 2005
Accepted:
October 18, 2005

Abstract

Measurement of estradiol is useful in women undergoing ovarian stimulation for in vitro fertilization and embryo transfer (IVF-ET). The analytical performance of a new two-step estradiol assay (ADVIA Centaur® estradiol-6 III from Bayer Diagnostics) was evaluated in 41 sera from 11 women undergoing ovarian stimulation. The results were compared to those obtained with two radioimmunoassays (RIAs; RIA Estradiol Immunotech IM 1663 from Beckmann Coulter and Coat-A-Count Estradiol from Diagnostic Products Corporation) and with one chemiluminescent immunoassay (CLIA; ADVIA Centaur® estradiol-6). The ADVIA Centaur® estradiol-6 III assay was the most sensitive assay, with a functional sensitivity of 55 pmol/L. Within- and between-run coefficients of variation calculated for the new ADVIA Centaur® assay ranged from 3.3% to 9%, which was better than the precision obtained for the other assays. A dilution test showed serum interferences when estradiol was measured in non-diluted samples. No statistical difference was observed between the estradiol results obtained in diluted sera with the new two-step ADVIA Centaur® assay and those measured with the Immunotech RIA and the other CLIA. In conclusion, this new, two-step estradiol assay performed on the ADVIA Centaur® system displays suitable sensitivity, precision and intermethod agreement with the Immunotech RIA for the measurement of serum estradiol concentrations in women undergoing ovarian stimulation and IVF-ET. For correct linearity, estradiol measurement should be performed on diluted samples.

Keywords: estradiol; immunoassay; ovarian stimulation; sensitivity