Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
April 2006
ISSN:
1437-4331
DOI:
10.1515/CCLM.2006.087

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Drug screening in urine by cloned enzyme donor immunoassay (CEDIA) and kinetic interaction of microparticles in solution (KIMS): a comparative study

Lutz Schwettmann1 / Wolf-Rüdiger Külpmann2 / Christian Vidal3

1.

2.

3.

Corresponding author: W.R. Külpmann, Medizinische Hochschule Hannover, Klinische Chemie, Carl-Neuberg-Str.1, 30625 Hannover, Germany Phone: +49-511-5326614, Fax: +49-511-5325671

Citation Information: Clinical Chemical Laboratory Medicine. Volume 44, Issue 4, Pages 479–487, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2006.087, April 2006

Publication History:
Received:
November 17, 2005
Accepted:
January 15, 2006

Abstract

Two commercially available drug-screening assays were evaluated: the Roche kinetic interaction of microparticles in solution (KIMS) assay and the Microgenics cloned enzyme donor immunoassay (CEDIA). Urine samples from known drug-abuse patients were analyzed for amphetamines, barbiturates, benzodiazepines, benzoylecgonine, cannabinoids, LSD, methadone and opiates. Samples with discordant findings for the two assays were analyzed by gas chromatography/mass spectrometry (GC/MS) or gas chromatography/electron capture detection (GC/ECD). Amphetamines showed 96.0% concordant results, with two false positive findings by CEDIA, three by KIMS and a further two false negatives by KIMS. Barbiturates showed 99.4% concordant results, with one false negative by KIMS. Benzodiazepines showed 97.4% concordant results, with two false negatives by KIMS (cutoff 100 μg/L, CEDIA cutoff 300 μg/L). Benzoylecgonine showed 17.8% concordant positive and 82.2% concordant negative results and no false finding by either assay. Cannabinoids showed 99.3% concordant results, with one sample negative by KIMS at a cutoff of 50 μg/L and positive by CEDIA (cutoff 25 μg/L). For LSD, 6.7% of findings were not in agreement. Methadone showed 97.5% concordant results, with two false positives by CEDIA, and one false positive and one false negative by KIMS. Opiates showed 96.9% concordant results, with no false KIMS results, but four false positives by CEDIA. The results indicate that the agreement of the CEDIA and KIMS results for the eight drugs is rather good (93.3–100%).

Keywords: cloned enzyme donor immunoassay (CEDIA); drug screening; gas chromatography/mass spectrometry (GC/MS); kinetic interaction of microparticles in solution (KIMS); solid phase micro extraction (SPME)

Comments (0)

Please log in or register to comment.