Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
January 2007
ISSN:
1437-4331
DOI:
10.1515/CCLM.2007.008

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Comparison of four commercial quantitative HIV-1 assays for viral load monitoring in clinical daily routine

Patrick Braun1 / Robert Ehret2 / Frank Wiesmann3 / Frauke Zabbai4 / Mechthild Knickmann5 / Rainer Kühn6 / Sven Thamm7 / Gerald Warnat8 / Heribert Knechten9

1.

2.

3.

4.

5.

6.

7.

8.

9.

Corresponding author: Patrick Braun, PZB Aachen, Aachen, Germany Phone: +49-241-4709725,

Citation Information: Clinical Chemical Laboratory Medicine. Volume 45, Issue 1, Pages 93–99, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2007.008, January 2007

Publication History:
Received:
May 9, 2006
Accepted:
September 28, 2006
Published Online:
2007-01-24

Abstract

Background: Quantification of viral load (VL) is standard for monitoring HIV-1 therapy and is crucial before deciding whether to switch or to continue a current antiretroviral regimen.

Methods: We compared the performance of the four most widely used commercial viral-load assays, COBAS Amplicor Monitor v1.5, Versant HIV-1 RNA 3.0, Abbott RealTime HIV-1 and Cobas AmpliPrep/Cobas TaqMan HIV-1 (CAP/CTM), in terms of intra- and inter-assay variability, as well as hands-on-time, specificity and ability to quantify group M subtypes.

Results: Although linearity and correlation were confirmed for the assays and comparable sensitivity and specificity were verified for genetically diverse HIV-1 subtypes, demonstrating suitability for monitoring of HIV group M isolates, the viral loads obtained showed variations, with a mean difference of 0.1–0.4 log, depending on the system used.

Conclusions: Although sensitivity and precision were confirmed for all the systems, differences between them should be taken into account when viral load monitoring of the same person is performed using different systems.

Clin Chem Lab Med 2007;45:93–9.

Keywords: HIV-1; monitoring; quantification; real-time PCR; viral load

Comments (0)

Please log in or register to comment.