Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
October 2007
ISSN:
1437-4331
DOI:
10.1515/CCLM.2007.309

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Redefining functional sensitivity of thyroglobulin assay on Immulite platform: implications in thyroid cancer management

Luca Giovanella1 / Luca Ceriani2 / Antonella Ghelfo3

1Department of Nuclear Medicine, Oncology Institute of Southern Switzerland, Bellinzona, Switzerland and Department of Clinical Chemistry, Oncology Institute of Southern Switzerland, Bellinzona, Switzerland

2Department of Nuclear Medicine, Oncology Institute of Southern Switzerland, Bellinzona, Switzerland

3Laboratory for Endocrinology and Tumour Markers, University Hospital and Fondazione Macchi, Varese, Italy

Corresponding author: Dr. med. Luca Giovanella, Department of Nuclear Medicine, Oncology Institute of Southern Switzerland, Via Ospedale 12, 6500 Bellinzona, Switzerland Phone: +41-91-811-8672, Fax: +41-91-811-8250,

Citation Information: Clinical Chemical Laboratory Medicine. Volume 45, Issue 11, Pages 1523–1524, ISSN (Online) 14374331, ISSN (Print) 14346621, DOI: 10.1515/CCLM.2007.309, October 2007

Publication History:
Received:
2007-05-30
Accepted:
2007-07-10
Published Online:
2007-10-31

Abstract

Circulating thyroglobulin (Tg) measurement after thyrotropin stimulation is a pivotal tool in the management of patients affected by differentiated thyroid carcinoma. The Tg assay on Immulite platform has a declared functional sensitivity of 0.9 ng/mL and it is widely used in clinical practice and research on thyroid carcinoma. Recently, thyroglobulin measured during thyroxine treatment was found to be adequate for thyroid carcinoma follow-up if functional sensitivity at 0.2–0.3 ng/mL was reached by assay methods. Thus, the present study was then undertaken to evaluate the imprecision of Immulite Tg assay at very low concentrations. The detection limit was calculated on zero calibrator and Tg-free pooled sera replicates and was 0.14 and 0.16 ng/mL, respectively. Different serum pools with Tg concentrations ranging from 0.16 to 2.50 ng/mL were assayed according to the National Academy of Clinical Biochemistry guidelines to estimate functional sensitivity. By interpolating the imprecision profile with a coefficient of variation of 20%, the functional sensitivity was 0.36 ng/mL. The Immulite-Tg assay was directly compared with a high-sensitive immunoradiometric Tg assay in sera from 93 patients with thyroid carcinomas. No significant differences in sensitivity and specificity were observed by using the newly defined functional sensitivity. In conclusion, the Immulite Tg assay showed a lower functional sensitivity than expected and performed comparably to high-sensitive immunoradiometric assay in patients with thyroid carcinoma.

Clin Chem Lab Med 2007;45:1523–4.

Keywords: carcinoma; functional sensitivity; thyroglobulin; thyroid

Comments (0)

Please log in or register to comment.