Jump to ContentJump to Main Navigation

Online

Publication Date:
August 2008
ISSN:
1437-4331
DOI:
10.1515/CCLM.2008.291

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

Free Access

VolumeIssuePage

Issues

Standardization of troponin I measurements: an update

Mauro Panteghini1 / David M. Bunk2 / Robert H. Christenson3 / Alexei Katrukha4 / Robert A. Porter5 / Heinz Schimmel6 / Lili Wang7 / Jillian R. Tate8 /

1Center for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milano, Italy

2Chemical Science and Technology Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, USA

3Department of Pathology, University of Maryland School of Medicine, Baltimore, MD, USA

4HyTest Ltd., Turku, Finland

5Analytical Science Group, National Physical Laboratory, Teddington, UK

6Reference Materials Unit, Institute for Reference Materials and Measurements, Joint Research Center, European Commission, Geel, Belgium

7Biochemical Science Division, National Institute of Standards and Technology, Gaithersburg, MD, USA

8Pathology Queensland, Department of Chemical Pathology, Royal Brisbane and Women's Hospital, Herston, Queensland, Australia

Corresponding author: Prof. Mauro Panteghini, Laboratorio Analisi Chimico Cliniche, Ospedale Luigi Sacco, Via GB Grassi 74, 20157 Milano, Italy Phone: +39-02-3904-2806, Fax: +39-02-503-19835,

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 46, Issue 11, Pages 1501–1506, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2008.291, August 2008

Publication History:
Received:
2008-05-28
Accepted:
2008-07-08
Published Online:
2008-08-29

Abstract

Standardization of cardiac troponin I (cTnI) measurement is important because of the central role for diagnosis of myocardial infarction. In blood, cTnI is present as a heterogeneous mixture of different molecular species. The analytical problem caused by this heterogeneity may be circumvented by recognition of a unique, invariant part of the molecule that is common to all components of the mixture. Antibodies used for the development of cTnI assays should selectively recognize epitopes within this invariant part, leading to a consequential increase in the homogeneity of immunoassay reactivity. This should be associated with the use of a reference material that represents the natural and major antigen in blood after tissue release, i.e., the troponin complex. Although a primary reference material for cTnI is available, studies indicate that cTnI assays remain without harmony after recalibration using this material. To achieve closer comparability of cTnI values between assays, the use of a secondary reference material, consisting of a panel of human serum pools, is proposed for use by manufacturers to calibrate their assays. To assign true cTnI concentration values to this secondary reference material, establishment of a reference measurement procedure for cTnI is required. A practical approach to the development of a reference procedure could be to design an immunochemical assay with well-characterized specificity to the invariant part of the cTnI molecule and calibrated using the primary reference material.

Clin Chem Lab Med 2008;46:1501–6.

Keywords: calibration; commutability; reference material; traceability; troponin I

Comments (0)