Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
October 2008
ISSN:
1437-4331
DOI:
10.1515/CCLM.2008.338

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Development and validation of a high-performance liquid chromatography assay for posaconazole utilizing solid-phase extraction

Dominic Störzinger1 / Stefanie Swoboda2 / Christoph Lichtenstern3 / Carsten Müller4 / Markus A. Weigand5 / Torsten Hoppe-Tichy6

1Pharmacy Department, University Hospital of Heidelberg, Heidelberg, Germany

2Pharmacy Department, University Hospital of Heidelberg, Heidelberg, Germany

3Department of Anaesthesiology, University Hospital of Heidelberg, Heidelberg, Germany

4Department of Pharmacology, University Hospital of Cologne, Cologne, Germany

5Department of Anaesthesiology, University Hospital of Heidelberg, Heidelberg, Germany

6Pharmacy Department, University Hospital of Heidelberg, Heidelberg, Germany

Corresponding author: Dominic Störzinger, Pharmacy Department, University Hospital of Heidelberg, Im Neuenheimer Feld 670, 69120 Heidelberg, Germany Phone: +49-6221-5638119, Fax: +49-6221-565343,

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 46, Issue 12, Pages 1747–1751, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2008.338, October 2008

Publication History:
Received:
2008-06-18
Accepted:
2008-08-21
Published Online:
2008-10-31

Abstract

Background: Posaconazole is a new broad-spectrum triazole antifungal drug that is used in prophylaxis and therapy of opportunistic fungal infections in immunocompromised patients. Up to now, it is available as an oral suspension only. Due to variable systemic availability known from other azoles, such as itraconazole, it is important to measure blood levels, especially in patients undergoing abdominal surgery which may influence the intestinal resorption.

Methods: A sensitive and selective high-performance liquid chromatography method for the precise determination of posaconazole and the internal standard clotrimazole in human plasma was developed and validated. Samples were extracted using solid-phase extraction and separated on a reversed-phase C8 column (150×4.6 mm, 5 μm) using phosphate buffer (pH 6.7, 0.04 M):acetonitrile:methanol (43:49:8, v/v/v) as mobile phase. UV detection was performed at 260 nm.

Results: This method showed that a lower limit of quantification was 50 ng/mL and the limit of detection 3 ng/mL. Linearity was tested in the range from 50 to 5000 ng/mL (r2=0.9998). Mean recovery was 86%.

Conclusions: The method proved to be a useful tool for therapeutic drug monitoring. It is specific, precise and showed excellent reproducibility as well as a favourable accuracy.

Clin Chem Lab Med 2008;46:1747–51.

Keywords: analytics; antifungal agents; posaconazole; reversed-phase chromatography; solid-phase-extraction

Comments (0)

Please log in or register to comment.