Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
August 2010
ISSN:
1437-4331
DOI:
10.1515/cclm.2010.287

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Automated assay for non-transferrin-bound iron in serum samples

Marija Prezelj1 / Bojan Knap2

1Institute of Clinical Chemistry and Biochemistry, University Medical Centre Ljubljana, Ljubljana, Slovenia

2Division of Internal Medicine, Department of Nephrology, University Medical Centre Ljubljana, Ljubljana, Slovenia

Corresponding author: Marija Prezelj, Institute of Clinical Chemistry and Biochemistry, University Medical Centre Ljubljana, Njegoševa 4, 1000 Ljubljana, Slovenia Phone: +386-1-5222443, Fax: +386-1-5225131,

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 48, Issue 10, Pages 1427–1432, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/cclm.2010.287, August 2010

Publication History:
Received:
2009-07-16
Accepted:
2010-05-09
Published Online:
2010-08-13

Abstract

Background: Non-transferrin-bound iron (NTBI) is a powerful promoter of free radical damage and highly toxic to biological systems, resulting in oxidative damage to proteins, lipids and DNA.

Methods: This assay is based on the binding of serum NTBI by the chelator nitrilotriacetic acid (NTA) and measurement of the ultrafiltrated Fe-NTA complex with the ferrozine reagent kit by a biochemical analyzer. To determine NTBI at extremely low concentrations, the program parameters for serum iron measurement were modified.

Results: Linearity was up to 15 μmol/L with analytical recovery of 93%–103%. The limit of detection was 0.076 μmol/L. The within-run coefficient of variation was 2.37%, 1.23%, and 0.812% at concentrations of 0.338, 1.717, and 5.916 μmol/L, respectively. NTBI concentrations measured after exercise in samples obtained from 14 rowers, divided into two groups, were substantially higher in all samples. The median NTBI concentrations (range) before and after exercise were 0.197 (–0.11 to 0.58), and 3.353 (2.39–8.97) μmol/L, respectively, in older rowers and 0.197 (–0.18 to 1.17), and 1.360 (0.47–2.49) μmol/L, respectively, in younger rowers.

Conclusions: With the described modification for serum iron determination, NTBI can be measured with high sensitivity and specificity. The data presented are illustrative examples of the applicability of this assay.

Clin Chem Lab Med 2010;48:1427–32.

Keywords: exercise; non-transferrin-bound iron; oxidative stress