Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
August 2010
ISSN:
1437-4331
DOI:
10.1515/cclm.2010.342

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Evaluation of the Sysmex UF-1000i® urine flow cytometer in the diagnostic work-up of suspected urinary tract infection in a Dutch general hospital

Wil C. van der Zwet1 / Jan Hessels2 / Fatih Canbolat1, 2 / Martine M.L. Deckers2

1Department of Medical Microbiology and Infection Control, Deventer Hospital, Deventer, The Netherlands

2Department of Clinical Chemistry, Deventer Hospital, Deventer, The Netherlands

Corresponding author: Wil C. van der Zwet, Department of Medical Microbiology and Infection Control, Deventer Hospital, Postbox 5001, 7400 GC Deventer, The Netherlands Phone: +31-570-535353, Fax: +31-570-501434,

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 48, Issue 12, Pages 1765–1771, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/cclm.2010.342, August 2010

Publication History:
Received:
2010-02-01
Accepted:
2010-05-29
Published Online:
2010-08-21

Abstract

Background: Automation and standardization of sediment analysis of urine samples by flow cytometry might serve as an alternative to labor-intensive laboratory methods, such as microscopic examination and culture. The Sysmex UF-1000i is a urine flow cytometer that uses two separate channels for counting blood cells and bacteria.

Methods: In this study, 358 urine samples were analyzed with the Sysmex UF-1000i in parallel with manual microscopy, Gram stain and bacterial culture, the latter considered the gold standard.

Results: Reproducibility for detection of white and red blood cells and bacteria was good, while detection of yeast proved unreliable. Depending on the definition of urinary tract in-fection (UTI) used, the negative predictive value and the per-centage of false-negative results were 100% and 0% [UTI ≥ 105 colony forming units (CFU)/mL] and 99% and 1.3%, (UTI ≥104 CFU/mL), respectively. Pre-screening with the Sysmex UF-1000i would have resulted in a reduction of bacterial culture by 42%. Carry over of bacteria between consecutive samples due to the use of fixed sample needle was observed, but did not result in false-positive interpretation of Sysmex UF-1000i results. Because of the occurrence of carry over, samples that have been analyzed with the Sysmex UF-1000i cannot be used for subsequent urine culture.

Conclusions: In conclusion, the Sysmex UF-1000i offers the possibility for screening high numbers of urine samples in a fast and standardized way, resulting in a reduction in workload and speeding the diagnostic process. It is not recommended for use in complicated patient populations, such as neutropenic patients and patients in whom yeast infection is suspected.

Clin Chem Lab Med 2010;48:1765–71.

Keywords: flow cytometry; Sysmex UF-1000i; urinary tract infection