Performance of a fully automated quantitative neopterin measurement assay in a routine voluntary blood donation setting

Peter Mayersbach1 / Dietmar Fuchs2 / Harald Schennach1

1Central Institute of Blood Transfusion and Immunology, University Hospital, Innsbruck, Austria

2Division of Biological Chemistry, Biocenter, Innsbruck Medical University, Innsbruck, Austria

Corresponding author: Prim. Doz. Dr. Harald Schennach, Central Institute of Blood Transfusion and Immunology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria Phone: +43 50504 22930, Fax: +43 50504 22934,

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 48, Issue 3, Pages 373–377, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2010.072, December 2009

Publication History

Received:
2009-09-18
Accepted:
2009-11-05
Published Online:
2009-12-18

Abstract

Background: Acute virus infections are indicated by increased serum neopterin concentrations. Testing of blood donations for increased neopterin was introduced in the Austrian Tyrol in 1986 and throughout Austria in 1994 to improve the safety of blood transfusions. Radioimmunoassay (RIA) was the first available test, and the 98th percentile for neopterin concentrations from 76,500 donations was defined as the cut-off threshold, excluding donations with neopterin ≥10 nmol/L. When ELISAs were introduced on fully automated test systems to measure neopterin concentrations, results were generally higher and the cut-off was adjusted up to 12 nmol/L.

Methods: In early 2006, new equipment (Hamilton Microlab Star® pipettor+Dade Behring ELISA Processor III, BEP III®) became available which monitors sample and reagent volumes for each uptake and dispense, and takes the viscosity of the fluids into account. Using this system, the performance of neopterin determinations was evaluated over 21 months and compared to earlier data.

Results: When the new apparatuses were introduced, an immediate decrease in mean neopterin concentrations and the percentage of samples with neopterin concentrations ≥10 nmol/L was observed. The 55,516 measurements performed in 2007 showed a mean value of 5.5 nmol/L. Neopterin in 680 donations (1.23%) were ≥10 nmol/L.

Conclusions: The new Hamilton diluter increased the accuracy of the neopterin test procedure. Results are now identical with those of RIA and ELISA when run in a semi-automated manner. Differences in pipetting performance of standards and samples are considered as one possible explanation for the earlier discrepancies seen with the automated apparatus.

Clin Chem Lab Med 2010;48:373–7.

Keywords: blood donations; ELISA; neopterin; performance; screening

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
Sonia Centi, Sara Tombelli, Mariarita Puntoni, Claudio Domenici, Milan Franek, and Ilaria Palchetti
Talanta, 2015, Volume 134, Page 48
[2]
H. Kofler, K. Kurz, G. Grander, and D. Fuchs
International Archives of Allergy and Immunology, 2012, Volume 159, Number 4, Page 416
[3]
Giorgio Ciprandi, Mara De Amici, Gianluigi Marseglia, and Dietmar Fuchs
International Immunopharmacology, 2010, Volume 10, Number 11, Page 1474
[4]
Giorgio Ciprandi, Mara De Amici, Mariangela Tosca, and Dietmar Fuchs
Human Immunology, 2010, Volume 71, Number 9, Page 911
[5]
Ursula Sauer, Patrick Domnanich, and Claudia Preininger
Analytical Biochemistry, 2011, Volume 419, Number 1, Page 46
[6]
M. Elizabeth Sublette, Hanga C. Galfalvy, Dietmar Fuchs, Manana Lapidus, Michael F. Grunebaum, Maria A. Oquendo, J. John Mann, and Teodor T. Postolache
Brain, Behavior, and Immunity, 2011, Volume 25, Number 6, Page 1272
[7]
Harald Mangge, Florian Freytag, Gunter Almer, Daniel Weghuber, Carmen Bauer-Denk, and Dietmar Fuchs
Journal of Obesity, 2011, Volume 2011, Page 1
[8]
Ivo Cernoch, Erwin Schleicher, and Milan Franek
Analytical and Bioanalytical Chemistry, 2011, Volume 399, Number 2, Page 979
[9]
G. Ciprandi, M. De Amici, L. Berardi, M. Vignini, S. Caimmi, A. Marseglia, G. Marseglia, and D. Fuchs
Clinical and Experimental Dermatology, 2011, Volume 36, Number 1, Page 85

Comments (0)

Please log in or register to comment.