Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
March 2010
ISSN:
1437-4331
DOI:
10.1515/cclm.2010.133

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Performance characteristics of a microfluidic Lab-on-Chip electrophoresis system for high-density lipoprotein (HDL) subfraction separation and measurement

Dan-Hui D. Yang1 / Yves Konigshofer1 / Jude Dike1 / Elaine Chang2 / Odilo Mueller1

1Agilent Technologies, Inc., Santa Clara, CA, USA

2Currently at Siemens Medical Solutions USA, Inc., Knoxville, TN, USA

Corresponding author: Dan-Hui D. Yang, Agilent Technologies, Inc., 5301 Stevens Creek Blvd., 3U-WG, Santa Clara, CA 95051, USA Fax: +1-408-553-7100,

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 48, Issue 6, Pages 883–889, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/cclm.2010.133, March 2010

Publication History:
Received:
2009-10-27
Accepted:
2010-01-08
Published Online:
2010-03-19

Abstract

Background: High-density lipoprotein (HDL) is believed to be protective against coronary heart disease (CHD). HDL is comprised of different subfractions. Of these, HDL 2b is believed to be the most important in preventing CHD. Current methods for HDL subfraction measurements are not standardized and often exhibit poor analytical performance, which can limit their usefulness in clinical practice.

Methods: We have developed a microfluidic Lab-on-Chip electrophoresis system for serum HDL subfraction measurements. Linear polymers are used as a sieving buffer for HDL particle separation. Nine samples and two controls can be analyzed in 30 min. The percent HDL 2b that comprises total high-density lipoprotein cholesterol (HDL-C) is reported.

Results: Samples with HDL-C of 0.259–2.072 mmol/L could be evaluated for percent HDL 2b with coefficient of variations (%CVs) below 8%. Total precision was typically below 1.5% and linearity was observed between 8% and 32% HDL 2b. Measurements were not affected by many therapeutic and biological compounds. Consistent results were obtained by three laboratories and showed r2 values between 0.93 and 0.95.

Conclusions: The assay allows for easy and reproducible measurement of percent HDL 2b. The experimental procedure and small size of the instrumentation needed for measurement make it viable in clinical settings.

Clin Chem Lab Med 2010;48:883–9.

Keywords: electrophoresis; high-density lipoprotein (HDL) 2b; HDL subfractions; Lab-on-Chip

Comments (0)

Please log in or register to comment.