Jump to ContentJump to Main Navigation
Show Summary Details

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM)

Editor-in-Chief: Plebani, Mario

Ed. by Gillery, Philippe / Lackner, Karl J. / Lippi, Giuseppe / Melichar, Bohuslav / Payne, Deborah A. / Schlattmann, Peter / Tate, Jillian R.


IMPACT FACTOR increased in 2015: 3.017
Rank 5 out of 30 in category Medical Laboratory Technology in the 2014 Thomson Reuters Journal Citation Report/Science Edition

SCImago Journal Rank (SJR) 2015: 0.873
Source Normalized Impact per Paper (SNIP) 2015: 0.982
Impact per Publication (IPP) 2015: 2.238

249,00 € / $374.00 / £187.00*

Online
ISSN
1437-4331
See all formats and pricing

 


Select Volume and Issue
Loading journal volume and issue information...

Sensitivity and specificity of the high fluorescent lymphocyte count-gate on the Sysmex XE-5000 hematology analyzer for detection of peripheral plasma cells

1 / Gert Jan Vrielink1 / Nicole Tjon-a-Tsoi1 / Henriët Hendriks1 / Wim de Kieviet1 / Edwin ten Boekel1

1Clinical Laboratory, Sint Lucas Andreas Hospital, Amsterdam, The Netherlands

Corresponding author: Dr. E. van Mirre, PhD, Clinical Laboratory, Sint Lucas Andreas Hospital, Jan Tooropstraat 164, 1061 Amsterdam, The Netherlands

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 49, Issue 4, Pages 685–688, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/CCLM.2011.100, March 2011

Publication History

Received:
2010-07-15
Accepted:
2010-10-25
Published Online:
2011-03-02

Abstract

Background: Plasma cells are one of the end products of the B-lymphocyte mediated immune response. These cells normally reside in the bone marrow or some peripheral lymphoid tissues. Increased numbers of plasma cells in the blood, usually indicates pathology such as infection, auto-immunity or haematological malignancy. Therefore, the ability to measure plasma cells (PCs) on an automated cell analyzer might be advantageous.

Methods: The performance of the Sysmex XE-5000 leukocyte differential channel [high fluorescent lymphocyte count (HFLC) area] was evaluated for the ability to detect plasma cells in peripheral blood and compared to the detection of plasma cells by flow cytometric analyses.

Results: Our results show that the HFL count from the XE-5000 correlates (R2=0.8) with the number of PCs in peripheral blood, but detects PCs with moderate to good sensitivity (88.9%) and specificity (87.8%).

Conclusions: The Sysmex XE-5000 is suitable for screening blood samples for the presence of elevated number of plasma cells in peripheral blood, but the actual quantification needs to be confirmed by flow cytometry.

Keywords: flow cytometry; hematology analyzer; high fluorescent lymphocyte count (HFLC); plasma cells