Jump to ContentJump to Main Navigation

Online

192,00 € / $269.00*

* Prices subject to change. Shipping costs will be added.
Publication Date:
06 10 2011
ISSN:
1437-4331
DOI:
10.1515/cclm.2011.740

See all formats and pricing

Print
List price
Euro [D] 1487.00
RRP for USA, Canada, Mexico
US$ 2231.00 *
Online
List price
Euro [D] 192.00
RRP for USA, Canada, Mexico
US$ 269.00 *
Print + Online
List price
Euro [D] 1710.00
RRP for USA, Canada, Mexico
US$ 2565.00 *
*Prices subject to change. Shipping costs will be added.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

null Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2010: 2.069
Rank 9 out of 30 in category Medical Laboratory Technology in the 2010 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

A risk-analysis approach to the evaluation of analytical quality

1 / Cappelletti, Piero 2 / Caputo, Marco 3 / Di Serio, Francesca 4 / Messeri, Gianni 5 / Ottomano, Cosimo 6 / Plebani, Mario 7 / Soffiati, Giuliano 8

1Diagnostica e Ricerca San Raffaele, San Raffaele Scientific Institute, Milan, Italy

2Laboratorio di Patologia Clinica, Azienda Ospedaliera, Pordenone, Italy

3Department of Diagnostic Services, Orlandi General Hospital, Bussolengo, Italy

4Department of Clinical Pathology I, University Hospital of Bari, Italy

5Dipartimento di Diagnostica di Laboratorio, Laboratorio Generale, University Hospital Careggi, Florence, Italy

6Dipartimento di Medicina di Laboratorio, Ospedali Riuniti di Bergamo, Laboratorio Analisi, Bergamo, Italy

7Dipartimento Medicina di Laboratorio, University Hospital of Padua, Italy

8Laboratorio di Chimica Clinica ed Ematologia, Ospedale San Bortolo, Vicenza, Italy

Corresponding author: Ferruccio Ceriotti, Diagnostica e Ricerca San Raffaele, Via Olgettina 60, 20132 Milano, Italy Phone: +39 02 26432282, Fax: +39 02 25432640

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 50, Issue 1, Pages 67–71, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/cclm.2011.740, October 2011

Publication History:

Received: 30/08/2011;
Accepted: 17/09/2011;
Published Online: 22/03/2012

Abstract

Background: Setting specifications for analytical quality is always difficult. The risk-management approach might be a way to do so. In this approach, the definition of the required analytical quality is based on the evaluation of patient risk. Risk derives from the probability of error and from the damage that such an error might cause.

Methods: Eight Italian laboratories took part in this experiment. Measurements of glucose and total calcium were taken as examples. Analytical quality was evaluated using a specific ring trial with a frozen serum pool and by means of internal quality-control data. The total allowable error was defined according to biological variation specifications. The probability of error was extracted from the imprecision and comparative bias data of each laboratory. The damage caused by a wrong result was evaluated using the absolute probability judgment approach.

Results: According to the iso-risk plots (standardized hyperboles on a graph where the x-axis represents damage and the y-axis represents probability) for glucose, all the laboratories were working with an analytical quality that guaranteed low risk for patients. On the contrary, for total calcium none of the laboratories exhibited sufficient quality to guarantee low risk for patients, the presence of bias being the most relevant problem.

Conclusions: The results seem to demonstrate the applicability of the risk approach to the analytical phase, indicating a new possible way to define analytical quality targets.

Keywords: analytical quality; quality specifications; risk analysis

Comments (0)

Please log in or register to comment.