Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
December 2011
ISSN:
1437-4331
DOI:
10.1515/cclm.2011.830

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

The performance of high sensitivity troponin for the diagnosis of acute myocardial infarction is underestimated

1 / Chris M. Florkowski1 / Ian G. Crozier1 / Martin P. Than1

1Department of Cardiology, Christchurch Hospital, Christchurch, New Zealand

Corresponding author: Sally J. Aldous, Department of Cardiology, Christchurch Hospital, Riccarton Road, Christchurch, New Zealand Fax: +64 33641415

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 50, Issue 4, Pages 727–729, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/cclm.2011.830, December 2011

Publication History:
Received:
2011-09-25
Accepted:
2011-11-21
Published Online:
2011-12-17

Abstract

Background: Many papers evaluating high sensitivity troponin assays make the diagnosis of myocardial infarction based on conventional troponin assays in clinical use at the time of recruitment. Such analyses often do not show superiority of high sensitivity assays compared with contemporary assays meeting precision guidelines.

Methods: Three hundred and twenty-two patients presenting to the emergency department between November 2006 and April 2007 for evaluation for acute coronary syndrome had serial (0 h and >6 h) bloods taken to compare troponin assays (Roche hsTnT, Abbott TnI, Roche TnT and Vitros TnI). The diagnosis of myocardial infarction was made using each troponin assay separately with which that same assay was analysed for diagnostic performance.

Results: The rate of myocardial infarction would be 38.9% using serial hsTnT, 31.3% using serial Abbott TnI, 27.1% using serial TnT and 26.4% using serial Vitros TnI. The baseline sensitivities (0 h) are 89.9% (85.2–93.3) for hsTnT, 77.9% (71.0–87.5) for Abbott TnI, 73.0% (65.6–78.7) for TnT and 86.8% (74.6–94.4%) for Vitros TnI. The specificities (peak 0 h and >6 h samples) are 93.1% (91.2–93.1) for hsTnT, 88.3% (86.5–88.3) for Abbott TnI, 92.2% (90.5–92.2) for TnT and 90.6% (70.1–90.6) for Vitros TnI.

Conclusions: hsTnT has superior sensitivity for myocardial infarction than even assays at or near guideline precision requirements (Abbott and Vitros TnI). The specificity of hsTnT assay is not as poor as previous analyses suggest.

Keywords: high sensitivity troponin; myocardial infarction

Comments (0)

Please log in or register to comment.