Jump to ContentJump to Main Navigation

Online

249,00 € / $374.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
November 2011
ISSN:
1437-4331
DOI:
10.1515/cclm.2012.799

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 249.00
RRP for USA, Canada, Mexico
US$ 374.00 *
Print
Individual Subscription Online only
Euro [D] 1577.00
RRP for USA, Canada, Mexico
US$ 2365.00 *
Print + Online
Individual Subscription Online only
Euro [D] 1893.00
RRP for USA, Canada, Mexico
US$ 2838.00 *
*Prices subject to change. Shipping costs will be added if applicable.

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the International Federation of Clinical Chemistry and Laboratory Medicine and the European Federation of Clinical Chemistry and Laboratory Medicine

Editor-in-Chief: Plebani, Mario

Editorial Board Member: Lippi, Giuseppe / Gillery, Philippe / Kazmierczak, Steven / Lackner, Karl J. / Melichar, Bohuslav / Siest, Gérard / Whitfield, John B. / Abi Fadel, Marianne / Alvarez Menendez, Francisco V. / Azzazy, Hassan M.E. / Diamandis, Eleftherios P. / Eckardstein, Arnold / Favaloro, Emmanuel J. / Griesmacher, Andrea / Herrmann, Wolfgang / Hoffmann, Johannes J.M.L. / Hooijkaas, Herbert / Ichihara, Kiyoshi / Kaabachi, Naziha / Kim, Jeong-Ho / Korte, Wolfgang / Kroupis, Christos / Lai, Leslie Charles / Lam, Wai Kei Christopher / Marc, Janja / Miyoshi, Eiji / Özben, Tomris / Palicka, Vladimir / Panteghini, Mauro / Queralto, Jose M. / Scartezini, Marileia / Simundic, Ana-Maria / Tsongalis, Gregory J. / Wallemacq, Pierre E. / Yan, Shengkai / Young, Ian S. / Chiu, Rossa Wai Kwun / Ghosh, Debabrata / Kappelmayer, Janos / Lehmann, Sylvain / Sypniewska, Grazyna

12 Issues per year

Increased IMPACT FACTOR 2011: 2.150
Rank 10 out of 32 in category Medical Laboratory Technology in the 2011 Thomson Reuters Journal Citation Report/Science Edition

VolumeIssuePage

Issues

Determination of the biological variation of S100β and lactate dehydrogenase in disease-free patients with malignant melanoma

1 / Jesús Montesinos2 / Josefina Franquesa1 / Maria Sala1 / Cristina Fígols1 / Ana Miguel2 / Montserrat Domenech2

1Service of Clinical Chemistry, Department of Biological Diagnosis, Althaia, Xarxa Assistencial de Manresa, Manresa, Spain

2Service of Oncology, Althaia, Xarxa Assistencial de Manresa, Manresa, Spain

Corresponding author: Jaume Trapé, Service of Clinical Chemistry, Hospital Sant Joan de Déu, Althaia Xarxa, Assistencial de Manresa, Dr. Joan Soler, s/n 08243 Manresa, Catalonia, Spain Phone: +34938742112 ext 3242, Fax: +348751593

Citation Information: Clinical Chemistry and Laboratory Medicine. Volume 50, Issue 5, Pages 927–929, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: 10.1515/cclm.2012.799, November 2011

Publication History:
Received:
2011-04-19
Accepted:
2011-10-30
Published Online:
2011-11-26

Abstract

Background: Biological variation is important for determining analytical goals and for establishing the magnitude of change between two consecutive measurements. The aim of this study was to determine the biological variation for S100β and lactate dehydrogenase in patients diagnosed with malignant melanoma but without evidence of disease recurrence.

Methods: The biological variation of S100β and lactate dehydrogenase was estimated from a mean of four consecutive measurements in 32 patients diagnosed with malignant melanoma but without evidence of disease recurrence, 3 months after tumor resection or 4 months after finishing adjuvant treatment. The mean sampling interval was 3 months.

Results: Mean concentrations of S100β and lactate dehydrogenase were 0.0557 μg/L and 6.3 μkat/L, respectively. Between-run analytical variation was 3.5% at 0.181 μg/L for S100β and 3.5% at 2.83 μkat/L for lactate dehydrogenase. Biological variations obtained for S100β and lactate dehydrogenase were 14.2% and 8.2%, respectively. The analytical goals (defined as 50% of biological variation) were 7.1% for S100β and 4.1% for lactate dehydrogenase.

Conclusions: The estimation of biological variation allows us to calculate analytical goals and reference change values. These are necessary tools for the correct interpretation of serial measurements in patient follow-up.

Keywords: analytical goals; biological variation; LDH; reference change value; S100

Comments (0)

Please log in or register to comment.