SFGP 2007 - An Analysis of the Mass Transfer in a Non-Dispersive Solvent Extraction Closed System

Zaher Albaraka1 / Dominique Trebouet2 / Marlene Tuna3 / Jose Miguel Loureiro4 / Michel Burgard5

1Département des Sciences Analytiques, IPHC, ULP, CNRS, 67087 Strasbourg Cedex 2, France, zalbaraka@hotmail.com

2Département des Sciences Analytiques, IPHC, ULP, CNRS, 67087 Strasbourg Cedex 2, France, trebouetd@ecpm.u-strasbg.fr

3Département des Sciences Analytiques, IPHC, ULP, CNRS, 67087 Strasbourg Cedex 2, France, marlene_tuna@msn.com

4LSRE, Department of Chemical Engineering, University of Porto, loureiro@fe.up.pt

5Département des Sciences Analytiques, IPHC, ULP, CNRS, 67087 Strasbourg Cedex 2, France, burgard@chimie.u-strasbg.fr

Citation Information: International Journal of Chemical Reactor Engineering. Volume 6, Issue 1, Pages –, ISSN (Online) 1542-6580, DOI: 10.2202/1542-6580.1632, January 2008

Publication History:
Published Online:
2008-01-28

The experimental study that concerns the extraction of alkali picrates with the bis-crown-6-calix[4]arene in a hollow fibers membrane contactor, validates a dynamic model described in a previous paper [D. Trébouet, Sep. Pur. Tech., 50, 97-106, 2006]. The experimental data confirm the influence of parameters as the aqueous and organic phase flowrates and module capacity factor on the sensitivity of the system. It appears clearly that the closed extraction system operates in an unsteady state until equilibrium is reached and so only dynamic models can represent mass transfer within reasonable accuracy. The overall mass transfer coefficient is determined even in the case where the equilibrium is described by a non-linear distribution isotherm. The determination of an overall mass transfer coefficient shows that the diffusion of the metal complex in the microporous is the main limiting step of mass transfer.

Keywords: hollow fiber contactor; liquid-liquid extraction; dynamic system; macrocycle extractant; mass transfer coefficient