Jump to ContentJump to Main Navigation

Online

49,00 € / $74.00*

* Prices subject to change. Shipping costs will be added if applicable.
Publication Date:
August 2010
ISSN:
1542-6580
DOI:
10.2202/1542-6580.2248

See all formats and pricing

Online
Individual Subscription Online only
Euro [D] 49.00
RRP for USA, Canada, Mexico
US$ 74.00 *
Print
Individual Subscription Online only
Euro [D] 218.00
RRP for USA, Canada, Mexico
US$ 294.00 *
Print + Online
Individual Subscription Online only
Euro [D] 262.00
RRP for USA, Canada, Mexico
US$ 353.00 *
*Prices subject to change. Shipping costs will be added if applicable.

New Journal at De Gruyter!

Ed. by de Lasa, Hugo / Xu, Charles

1 Issue per year

Increased IMPACT FACTOR 2011: 0.790

 

Oxygen Mass Transfer Coefficients in a Three-Phase Pulsed Plate Bioreactor

K.V. Shetty1 / G. Srinikethan2

1National Institute of Technology Karnataka, Surathkal, vidyaks68@yahoo.com

2National Institute of Technology Karnataka, Surathkal, srini@nitk.ac.in

Citation Information: International Journal of Chemical Reactor Engineering. Volume 8, Issue 1, Pages –, ISSN (Online) 1542-6580, DOI: 10.2202/1542-6580.2248, August 2010

Publication History:
Published Online:
2010-08-17

Volumetric oxygen mass transfer coefficient is a decisive parameter for the selection of any contactor as an aerobic bioreactor. A pulsed plate column with fixed bed of solids in interplate spaces is a recent innovation in the field of immobilized cell bioreactors. Volumetric oxygen mass transfer coefficients are determined in a three-phase pulsed plate column involving air and water phases and with a fixed bed of glass particles, which can serve as a surface for cell immobilization packed in the interplate spaces. The volumetric mass transfer coefficients obtained in this column range from 0.067 to 0.1495 s-1 in the range of air superficial velocities from 0.011 to 0.047m/s and vibrational velocities from 0.825 to 6cm/s. Volumetric oxygen mass transfer coefficient has increased with the increase in superficial air velocity and vibrational velocity. Empirical correlation relating kLa with these variables was developed. The volumetric oxygen mass transfer coefficient values in the three-phase pulsed plate column are found to be similar or higher than the literature reported values for conventional two-phase pulsed plate columns. The values of volumetric oxygen mass transfer coefficients in the three-phase pulsed plate column are of higher order of magnitude than the literature reported values of volumetric oxygen mass transfer coefficient for many other three-phase gas-liquid-solid reactors. The pulsed plate column with fixed bed of solids is proven to have all the potential to be used as an aerobic bioreactor with immobilized cells due to its better gas-liquid mass transfer characteristics.

Keywords: bioreactor; oxygen mass transfer coefficients; pulsed plate column; superficial air velocity; vibrational velocity

Comments (0)

Please log in or register to comment.