A 2-min at 4500 g rather than a 15-min at 2200 g centrifugation does not impact the reliability of 10 critical coagulation assays

Elodie Boissier 1 , Mathieu Sévin-Allouet 2 , Aurélie Le Thuaut 3 , Solène De Gaalon 2 , Marc Trossaërt 4 , Bertrand Rozec 5 , Karim Lakhal 5 ,  and Jean-Christophe Rigal 5
  • 1 Service d’hématologie biologique, Hôpital Laënnec, Centre Hospitalier Universitaire de Nantes, Bd Jacques Monod, 44 093 Nantes Cedex 1, France
  • 2 Service de neurologie, Centre Hospitalier Universitaire de Nantes, Nantes, France
  • 3 Direction de la recherche, Centre Hospitalier Universitaire de Nantes, Nantes, France
  • 4 Service d’hématologie biologique, Centre Hospitalier Universitaire de Nantes, Nantes, France
  • 5 Service d’anesthésie-réanimation, Hôpital Laënnec, Centre Hospitalier Universitaire de Nantes, Nantes, France
Elodie Boissier, Mathieu Sévin-Allouet, Aurélie Le Thuaut, Solène De Gaalon, Marc Trossaërt, Bertrand Rozec, Karim Lakhal and Jean-Christophe Rigal

If the inline PDF is not rendering correctly, you can download the PDF file here.

  • 1.

    Adcock Funk DM, Hoefner DM, Kottke-Marchant K, Marlar RA, Szamosi DI, Warunek DJ. Collection, transport and processing of blood specimens for testing plasma-based coagulation assays and molecular hemostasis assays; approved guideline, 5th ed. Wayne PA: Institute CLS, CLSI document H21-A5, 2008.

  • 2.

    Polack B, Schved JF, Boneu B. Preanalytical recommendations of the ‘Groupe d’Etude sur l’Hemostase et la Thrombose’ (GEHT) for venous blood testing in hemostasis laboratories. Haemostasis 2001;31:61–8.

    • PubMed
    • Export Citation
  • 3.

    Mackie I, Cooper P, Lawrie A, Kitchen S, Gray E, Laffan M. Guidelines on the laboratory aspects of assays used in haemostasis and thrombosis. Int J Lab Hematol 2012;35:1–13.

    • PubMed
    • Export Citation
  • 4.

    Chandler WL, Ferrell C, Trimble S, Moody S. Development of a rapid emergency hemorrhage panel. Transfusion 2010;50:2547–52.

    • Crossref
    • PubMed
    • Export Citation
  • 5.

    Monneret D, Corlouer C, Bigot J, Atlan G, Alkouri R, Mestari F, et al. Comparison of a 10- vs. 15-min centrifugation time for chemical and immunochemical assays and impact on turnaround time in a hospital laboratory. Clin Chem Lab Med 2016;54:e117–21.

  • 6.

    Suchsland J, Friedrich N, Grotevendt A, Kallner A, Ludemann J, Nauck M, et al. Optimizing centrifugation of coagulation samples in laboratory automation. Clin Chem Lab Med 2014;52:1187–91.

    • PubMed
    • Export Citation
  • 7.

    Nelson S, Pritt A, Marlar RA. Rapid preparation of plasma for ‘Stat’ coagulation testing. Arch Pathol Lab Med 1994;118:175–6.

    • PubMed
    • Export Citation
  • 8.

    Pappas AA, Palmer SK, Meece D, Fink LM. Rapid preparation of plasma for coagulation testing. Arch Pathol Lab Med 1991;115:816–7.

    • PubMed
    • Export Citation
  • 9.

    Vassault A, Hulin A, Chapuzet E, Arnaud J, Giroud C. Verification/validation of the performances of analytical method. Ann Biol Clin (Paris) 2010;68:247–94.

    • PubMed
    • Export Citation
  • 10.

    Flaujac C, Marion S, Roussi J, Cambus J-P, de Maistre E, Stepanian A. Normes d’acceptabilité en hémostase. 2014. Available at: www.geht.org.

Purchase article
Get instant unlimited access to the article.
$42.00
Log in
Already have access? Please log in.


or
Log in with your institution

Journal + Issues

Clinical Chemistry and Laboratory Medicine ( CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor of over three. CCLM is the official journal of nine national clinical societies and associated with EFLM.

Search