SEARCH CONTENT

You are looking at 1 - 10 of 139 items :

Clear All

Abstract

The development of biosensors to identify molecular markers or specific genes is fundamental for the implementation of new techniques that allow the detection of specific Deoxyribonucleic acid (DNA) sequences in a fast, economic and simple way. Different detection techniques have been proposed in the development of biosensors. Electrical Bioimpedance Spectroscopy (EBiS) has been used for diagnosis and monitoring of human pathologies, and is recognized as a safe, fast, reusable, easy and inexpensive technique. This study proves the development of a complementary DNA (cDNA) biosensor based on measurements of EBiS and DNA's immobilization with no chemical modifications. The evaluation of its potential utility in the detection of the gene expression of three inflammation characteristic biomarkers (NLRP3, IL-1β and Caspase 1) is presented. The obtained results demonstrate that EBiS can be used to identify different gene expression patterns, measurements that were validated by Quantitative Polymerase Chain Reaction (qPCR). These results indicate the technical feasibility for a biosensor of specific genes through bioimpedance measurements on the immobilization of cDNA.

Abstract

Impedance cardiography (ICG) is a non-invasive method to evaluate several cardiodynamic parameters by measuring the cardiac-synchronous changes in the dynamic transthoracic electrical impedance. ICG allows us to identify and quantify conductivity changes inside the thorax by measuring the impedance on the thorax during a cardiac cycle. Pathologic changes in the aorta, like aortic dissection, will alter the aortic shape as well as the blood flow and consequently, the impedance cardiogram. This fact distorts the evaluated cardiodynamic parameters, but it could lead to the possibility to identify aortic pathology. A 3D numerical simulation model is used to compute the impedance changes on the thorax surface in case of the type B aortic dissection. A sensitivity analysis is applied using this simulation model to investigate the suitability of different electrode configurations considering several patient-specific cases. Results show that the remarkable pathological changes in the aorta caused by aortic dissection alters the impedance cardiogram significantly.

Abstract

Background

Young ballet dancers are at risk of health issues associated with altered nutritional status and of relative energy deficiency in sport compared to the general population.

Aim

To evaluate the nutritional status and body composition in ballet dancers.

Materials and methods

The study group consisted of 40 young ballet dancers (mean age 19.97 years). Height and weight were measured and body mass index was calculated in all subjects (mean BMI value 19.79 kg/m2, SD: 2.051). Body composition was estimated using the bioelectrical impedance method.

Results

The dancers’ fat-free mass was 47.33 kg (SD: 5.064) and, on the average, body fat represented the 15.92% (SD: 16.91) of their body weight.

Conclusions

Ballet dancers, who usually show significantly lower BMI values compared to the general population, also displayed body fat values under the suggested range. Some screening for altered nutritional status should be performed. In addition, education programs should be recommended in young ballet dancers, in order to inform about energy and nutrition requirements for health and training and to prevent malnutrition-related problems.

Abstract

There is a strong need for a non-invasive measurement technique that is capable of accurately identifying the physiological condition change or heterogeneity of subcutaneous adipose tissue (SAT) by localizing the abnormalities within the compartment. This paper aims to investigate the feasibility of Electrical Impedance Tomography (EIT) to assess the interstitial fluid in subcutaneous adipose tissue as an enhancement method of bioelectrical impedance spectroscopy (BIS). Here, we demonstrate the preliminary result of EIT with a wearable 16 electrodes sensor. The image-based reference EIT with fat weighted threshold method is proposed. In order to evaluate the performance of our novel method, a physiological swelling experiment is conducted, and Multi-Frequency Bioelectrical Impedance Analysis (MFBIA) is also applied as a comparison with EIT results. The experimental results showed that the proposed method was able to distinguish the physiological swelling condition and effectively to remove the unexpected background noise. Furthermore, the conductivity variation in the subcutaneous layer had a good correlation with extracellular water volume change from MFBIA data; the correlation coefficient R2 = 0.927. It is concluded that the proposed method provides a significant prospect for SAT assessment.

Abstract

Apnea is one of the deadliest diseases that can be prevented and cured if it is detected in time. In this paper, we propose a precise method for early detection of the obstructive sleep apnea (OSA) disease using the latest feature selection and extraction methods. The feature selection in this paper is based on the Dual tree complex wavelet (DT-CWT) coefficients of the ECG signals of several patients. The feature extraction from these coefficients is done using frequency and time techniques. The Feature selection is done using the spectral regression discriminant analysis (SRDA) algorithm and the classification is performed using the hybrid RBF network. A hybrid RBF neural network is introduced in this paper for detecting apnea that is much less computationally demanding than the previously presented SVM networks. Our findings showed a 3 percent improvement in the detection and at least a 30 percent reduction in the computational complexity in comparison with methods that have been presented recently.

Abstract

Nonhuman primates are often used in biomedical research and to investigate physiologic processes that occur in man. Impedance plethysmography was used to measure calf, thigh, pelvic, abdominal, and thoracic volume changes in ten Rhesus and eight squirrel monkeys during five-minute exposures to HUT and HDT at angles of 5, 10, and 20 degrees. Calf, rump and tail measurements were made in three squirrel monkeys at 10 and 20 degrees of HUT and HDT. Fluid volume changes in all segments of the Rhesus monkeys were found to change during HUT an HDT in direct relation to the angle of tilt used. However, the volume changes that occurred in the squirrel monkeys were found to be quite different. Their calf, thigh, and pelvic segments lost volume during both HUT and HDT while their abdominal and thoracic segments responded similarly to those of the Rhesus monkeys. These results and those of the calf/tail measurements of the squirrel monkeys suggest that they may utilize their tails as a compensatory reservoir during postural changes and therefore, may not be an appropriate animal model for man under some orthostatic test conditions.

Abstract

Impedance cardiography (ICG) is a non-invasive method of hemodynamic measurement, mostly known for estimation of stroke volume and cardiac output based on characteristic features of the signal. Compared with electrocardiography, the knowledge on the morphology of the ICG signal is scarce, especially with respect to age-dependent changes in ICG waveforms. Based on recordings from ten younger (20–29 years) and ten older (60–79) healthy human subjects after three different levels of physical activity, the typical interbeat ICG waveforms were derived based on ensemble averages. Comparison of these waveforms between the age groups indicates the following differences: a later initial upward deflection for the younger group, an additional hump in the waveform from many older subjects not presented in the younger group, and a more pronounced second wave in the younger group. The explanation for these differences is not clear, but may be related to arterial stiffness. Further studies are suggested to determine whether these morphological differences have clinical value.

Abstract

Overall survival of oncologic patients is strongly influenced by the incidence of malnutrition, with subsequent loss of muscle mass until sarcopenia. In this respect, the assessment of body composition has a pivotal role in order to manage the clinical consequences of muscle loss.

Aim:

This study focuses on the body composition assessment in oncologic patients, following a diet plan in order to detect and contrast neoplastic cachexia.

Materials and Method:

35 oncologic patients were enrolled and divided into two groups: 24 responders (R) and 11 non-responders (NR). Anthropometric data were collected and body composition was assessed through bioimpedentiometry. All patients received an individualized normocaloric diet. Energetic content was assigned on the basis of individual basal metabolic rate estimated by BIA. All patients were revaluated by anthropometry and bioimpedentiometry 3 and 6 months thereafter.

Results:

Comparing the two male groups R and NR after 6 months, the former maintained almost the same confidence interval, unlike the latter whose interval increased, indicating a light worsening both of body composition and of clinical conditions. Furthermore, in the same male responder group, an improvement of the phase angle (PhA), a positive prognostic factor, was found, with an average weight loss between 2,6 – 3 kg of fat mass (FM). Besides, data show how the R female group maintained the confidence interval unlike the NR female group, whose confidence interval remarkably increased, therefore indicating an important alteration of body composition and subsequently a clinical conditions worsening. Finally, comparing the NR male group with the NR female group after 6 months, a remarkable worsening of body composition (marker of tissue decay and damage) could be noticed in the latter group.

Conclusion:

After 6 months, NR patients show worse results (both in the body composition and in the clinical conditions) compared to the responders, with particularly worse results in females, probably because of a genetically determined sex-related smaller muscle cells and inferior muscular strength. A multidimensional assessment of oncologic patient is necessary, with a special attention to nutritional evaluation and body composition monitoring, in order to avoid malnutrition and subsequent further clinical worsening.

Abstract

Sixteen volunteers each drank 700 ml sugar-containing soft drink during two successive periods and the blood sugar was measured at 10 min intervals together with electrical impedance spectroscopy and near infrared spectroscopy (NIR). A maximum correlation of 0.46 was found for the electrical measurements but no clear separation between low and high blood glucose levels were found in the NIR measurements. The latter was attributed to the experimental design where the NIR probe was removed from the skin between each measurement.