Metrology for drug delivery

Peter Lucas and Stephan Klein

Abstract

In various recently published studies, it is argued that there are underestimated risks with infusion technology, i.e., adverse incidents believed to be caused by inadequate administration of the drugs. This is particularly the case for applications involving very low-flow rates, i.e., <1 ml/h and applications involving drug delivery by means of multiple pumps. The risks in infusing are caused by a lack of awareness, incompletely understood properties of the complete drug delivery system and a lack of a proper metrological infrastructure for low-flow rates. Technical challenges such as these were the reason a European research project “Metrology for Drug Delivery” was started in 2011. In this special issue of Biomedical Engineering, the results of that project are discussed.


Corresponding author: Peter Lucas, VSL, Dutch Metrology Institute, Thijsseweg 11, 2629JA Delft, The Netherlands, E-mail:

Acknowledgments

The research leading to the results discussed in this report has received funding from the European Metrology Research Program (EMRP). The EMRP is jointly funded by the EMRP participating countries within Euramet and the European Union.

References

[1] Abdul-Karim S, Schroeter J, Nestler B. Development and evaluation of a drug multiplexing infusion system. Biomed Eng-Biomed Tech 2014; 59: Track L, Issue s1.Search in Google Scholar

[2] Capes D, Kimble R. Fluctuations in syringe-pump infusions: association with blood pressure variations in infants. Am J Health Syst Pharm 1995; 52: 1646–1653.Search in Google Scholar

[3] Gezond wantrouwen bij infuuspompen. Nursing 2008; 30. Available at: .Search in Google Scholar

[4] IEC 60601-2-24:1992: Medical electrical equipment –Part 2-24: Particular requirements for the safety of infusion pumps and controllers.Search in Google Scholar

[5] Inspectie Voor de Gezondheidszorg. Risico’s van medische technologie onderschat. The Hague: Staatstoezicht op de Volksgezondheid, 2008.Search in Google Scholar

[6] ISO 7886-2:1996. Sterile hypodermic syringes for single use – Part 2: Syringes for use with power-driven syringe pumps. Available at: ISO.org.Search in Google Scholar

[7] Metrology for drug delivery. Available at: .Search in Google Scholar

[8] Ohashi K, Dalleur O, Dykes PC, Bates DW. Benefits and risks of using smart pumps to reduce medication error rates: a systematic review. Drug Saf 2014; 37: 1011–1020.Search in Google Scholar

[9] Riphagen B. Multi-infusion, multiple problems. Development, validation and application of a system based on spectral-photometry for measuring fluid dynamics of multi-infusion systems in neonatal intensive care units. Unpublished thesis. Twente: University of Twente, 2009.Search in Google Scholar

[10] Spieth S, Schumacher A, Trenkle F. Approaches for drug delivery with intracortical probes. Biomed Tech 2014; 59: 291–303.Search in Google Scholar

[11] Vaartjes SR, Teirlinck CJPM, Timmerman AMDE, Bastin FH, Franken M. Risk profile infusion technology (original title: “Risicoprofiel Infusietechnologie, Kwaliteitsdocument van de Nederlandse Vereniging voor Klinische Fysica”). Technical report NVKF. TNO, 2008.Search in Google Scholar

[12] 8th Workshop on Low Flows in Medical Technology. Available at: . Accessed on July 14, 2015.Search in Google Scholar

Received: 2014-11-7
Accepted: 2015-3-9
Published Online: 2015-4-16
Published in Print: 2015-8-1

©2015 by De Gruyter