Skip to content
Licensed Unlicensed Requires Authentication Published by De Gruyter November 20, 2015

Digital templating for THA: a simple computer-assisted application for complex hip arthritis cases

Mahmoud A. Hafez, Gad Ragheb, Adel Hamed, Amr Ali and Said Karim

Abstract

Introduction:

Total hip arthroplasty (THA) is the standard procedure for end-stage arthritis of the hip. Its technical success relies on preoperative planning of the surgical procedure and virtual setup of the operative performance. Digital hip templating is one methodology of preoperative planning for THA which requires a digital preoperative radiograph and a computer with special software.

Patients and methods:

This is a prospective study involving 23 patients (25 hips) who were candidates for complex THA surgery (unilateral or bilateral). Digital templating is done by radiographic assessment using radiographic magnification correction, leg length discrepancy and correction measurements, acetabular component and femoral component templating as well as neck resection measurement.

Results:

The overall accuracy for templating the stem implant’s exact size is 81%. This percentage increased to 94% when considering sizing within 1 size.

Conclusion:

Digital templating has proven effective, reliable and essential technique for preoperative planning and accurate prediction of THA sizing and alignment.


Corresponding author: Mahmoud A. Hafez, Faculty of Medicine, Orthopaedic Department, October 6 University, Cairo, Egypt, E-mail:

References

[1] Carter LW, Stovall DO, Young TR. Determination of accuracy of preoperative templating of noncemented femoral prostheses. J Arthroplasty 1995; 10: 507–513.10.1016/S0883-5403(05)80153-6Search in Google Scholar

[2] Clarke IC, Gruen T, Matos M, Amstutz HC. Improved methods for quantitative radiographic evaluation with particular reference to total-hip arthroplasty. Clin Orthop Relat Res 1976: 83–91.10.1097/00003086-197611000-00011Search in Google Scholar

[3] Conn KS, Clarke MT, Hallett JP. A simple guide to determine the magnification of radiographs and to improve the accuracy of preoperative templating. J Bone Joint Surg Br 2002; 84: 269–272.10.1302/0301-620X.84B2.0840269Search in Google Scholar

[4] D’Antonio JA. Preoperative templating and choosing the implant for primary THA in the young patient. Instr Course Lect 1994; 43: 339–346.Search in Google Scholar

[5] Eggli S, Pisan M, Muller ME. The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br 1998; 80: 382–390.10.1302/0301-620X.80B3.0800382Search in Google Scholar

[6] Gamble P, de Beer J, Petruccelli D, Winemaker M. The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplasty 2010; 25: 529–532.10.1016/j.arth.2009.04.011Search in Google Scholar

[7] Gonzalez Della Valle A, Slullitel G, Piccaluga F, Salvati EA. The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty 2005; 20: 51–58.10.1016/j.arth.2004.04.016Search in Google Scholar

[8] Gorski JM, Schwartz L. A device to measure X-ray magnification in preoperative planning for cementless arthroplasty. Clin Orthop Relat Res 1986; 302–306.10.1097/00003086-198601000-00043Search in Google Scholar

[9] Hafez MA, Schemitsch E. Templating for primary total hip arthroplasty. In: Waddell JP, editor. Operative techniques/hip Surgery. Elsevier. 2008: Sec II, Ch4, 53–65. http://www.elsevier.com/wps/find/bookdescription.cws_home/714605/description.10.1016/B978-1-4160-3850-4.50008-3Search in Google Scholar

[10] Hossain M, Lewis J, Sinha A. Digital pre-operative templating is more accurate in total hip replacement compared to analogue templating. Eur J Orthop Surg Traumatol 2008; 18: 577–580.10.1007/s00590-008-0356-zSearch in Google Scholar

[11] Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL. A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe? J Arthroplasty 2009; 24: 175–179.10.1016/j.arth.2007.11.019Search in Google Scholar

[12] Issa K, Pivec R, Boyd B, et al. Comparing the accuracy of radiographic preoperative digital templating for a second- versus a first-generation THA stem. Orthopedics 2012; 35: 1028–1034.10.3928/01477447-20121120-03Search in Google Scholar

[13] Jasty M, Henshaw RM, O’Connor DO, Harris WH. High assembly strains and femoral fractures produced during insertion of uncemented femoral components. A cadaver study. J Arthroplasty 1993; 8: 479–487.10.1016/S0883-5403(06)80213-5Search in Google Scholar

[14] Jay VP, McGrory BJ. A convenient method for preoperative templating. Am J Orthop (Belle Mead NJ) 1995; 24: 792.Search in Google Scholar

[15] Kniesel B, Konstantinidis L, Hirschmüller A, Südkamp N, Helwig P. Digital templating in total knee and hip replacement: an analysis of planning accuracy. Int Orthop 2013.10.1007/s00264-013-2157-1Search in Google Scholar

[16] Kosashvili Y, Shasha N, Olschewski E, et al. Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty. Can J Surg 2009; 52: 6–11.Search in Google Scholar

[17] Levine B, Fabi D, Deirmengian C. Digital templating in primary total hip and knee arthroplasty. Orthopedics 2010; 33: 797.10.3928/01477447-20100924-04Search in Google Scholar

[18] Linclau L, Dokter G, Peene P. Radiological aspects in preoperative planning and postoperative assessment of cementless total hip arthroplasty. Acta Orthop Belg 1993; 59: 163–167.Search in Google Scholar

[19] Oddy MJ, Jones MJ, Pendegrass CJ, Pilling JR, Wimhurst JA. Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs. J Bone Joint Surg Br 2006; 88: 581–585.10.1302/0301-620X.88B5.17184Search in Google Scholar

[20] Pullen WM, Whiddon DR. Accuracy and reliability of digital templating in primary total hip arthroplasty. J Surg Orthop Adv 2013; 22: 148–151.10.3113/JSOA.2013.0148Search in Google Scholar

[21] The B, Diercks RL, van Ooijen PM, van Horn JR. Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta Orthop 2005; 76: 78–84.10.1080/00016470510030364Search in Google Scholar

[22] The B, Verdonschot N, van Horn JR, van Ooijen PM, Diercks RL. Digital versus analogue preoperative planning of total hip arthroplasties: a randomized clinical trial of 210 total hip arthroplasties. J Arthroplasty 2007; 22: 866–870.10.1016/j.arth.2006.07.013Search in Google Scholar

[23] White SP, Shardlow DL. Effect of introduction of digital radiographic techniques on pre-operative templating in orthopaedic practice. Ann R Coll Surg Engl 2005; 87: 53–54.10.1308/1478708051540Search in Google Scholar

Received: 2014-11-1
Accepted: 2015-10-22
Published Online: 2015-11-20
Published in Print: 2016-10-1