Diagnosis of diabetes mellitus: reiterated responsibilities for the clinical laboratory

  • Philippe Gillery EMAIL logo , Giuseppe Lippi and Mario Plebani

Diabetes mellitus is a global burden for public health worldwide. The number of diabetic patients in 2012 was 371 million, and the expected number in 2030 is 552 million, which represents an increase of more than 50%. As specifically regards the US, 25.8 million children and adults (i.e., 8.3% of the population) are currently suffering from this condition [1]. The diagnosis of diabetes mellitus is therefore a key event for patient and society, owing to the severe consequences of the disease, which lead to an impaired quality of life for patients and high healthcare expenses for society.

For decades the diagnosis of diabetes mellitus was only based on the assessment of venous blood glucose, more specifically plasma glucose. The current World Health Organization (WHO) criteria indicate that diabetes mellitus is diagnosed by a concentration of fasting plasma glucose higher than 7.0 mmol/L (i.e., 1.26 g/L) repeated twice, or by random glycemia higher than 11.1 mmol/L (i.e., 2.0 g/L). Recently, hemoglobin A1c (HbA1c) has been proposed as a valuable tool for diagnosing this condition, in the presence of values higher than 48 mmol/mol (i.e., 6.5% of total Hb) [2]. This last criterion has then been endorsed by several international and national organizations (including the WHO), although some doubts remain [3].

Whatever the approach, the determination of glucose or HbA1c has to be performed by clinical laboratories. This implies that the means devoted by the clinical laboratory for glucose and HbA1c assays are well fitted to the goal. Glucose assay seems to be a simple and straightforward procedure. However, the need to use validated techniques is still required, and methods have to be carefully calibrated and traceable to reference measurement procedures [4]. Point of care testing (POCT) instruments have also been recently suggested as valuable tools for the diagnosis of this condition, as well as for a number of other human disorders [5]. In this issue, Freckmann et al. clearly show that these devices must be strictly evaluated and related to reference procedures like laboratory methods [6].

Besides, a classical but still critical topic is the preanalytical phase of glucose assay(s). In a paper published in this issue, Chan et al. show that the decrease of glucose concentration in blood samples was not proportional to the initial glucose values, as suggested by other studies, but that this reduction was constant [7]. The alteration of glucose concentration due to the action of glycolytic enzymes is significant and could substantially impair glucose values, thus leading to misclassification of patients with respect to the (real) diabetic status. Further support to this evidence comes from another study by Fobker, who shows that the stability of glucose varies widely using different types of tubes and additives [8]. A recently published article by Garcia Del Pino et al. confirms previous data on the straightforwardness and effectiveness of citric acid as an immediate inhibitor of glycolysis [9]. The authors reported significantly lower measured glucose concentrations in sodium fluoride (NaF) specimens than in paired citrate tubes, and the implementation of the new additive improved the quality of the diagnosis, achieving a statistical significance for gestational diabetes mellitus (GDM) screening. In a previous Editorial, Gambino and Bruns highlighted the need for additional studies about the effect of prompt inhibition of glycolysis on the diagnosis of diabetes, because the epidemiological studies that defined the diagnostic thresholds were based on the use of NaF tubes for collecting samples [10]. Szoke and colleagues provided further support to the need for revaluating the current cut-points derived from plasma glucose data using fluoride tubes. The leading take-home message is that compensatory changes in decision levels should be considered when clinical laboratories introduce commercially available collection tubes containing citrate buffer (VFC) [11].

The drawbacks of only using plasma glucose for diagnosing diabetes are well known to most working in the field of laboratory diagnostics, and are mainly attributable to the high vulnerability of this test to preanalytical variables, especially to the storage conditions and the presence of spurious hemolysis [12]. This is also reflected by the recent findings of Nielsen et al., who showed that the percentage of undiagnosed patients with diabetes may be reduced by approximately 2% with replacement of fasting plasma glucose with HbA1c [13]. A new era is probably dawning for the diagnosis of diabetes mellitus [3, 14], but the responsibilities for the clinical laboratory remain virtually unchanged.

Conflict of interest statement

Authors’ conflict of interest disclosure: The authors stated that there are no conflicts of interest regarding the publication of this article.

Research funding: None declared.

Employment or leadership: None declared.

Honorarium: None declared.


Corresponding author: Prof. Philippe Gillery , Laboratory of Pediatric Biology and Research, American Memorial Hospital, University Hospital of Reims, 47 rue Cognacq-Jay, 51092 Reims cedex, France, E-mail:

References

1. American Diabetes Association. Statistics about diabetes. Available from: http://www.diabetes.org/diabetes-basics/statistics/. Accessed on 17 April, 2014.Search in Google Scholar

2. American Diabetes Association. Diagnosis and classification of diabetes mellitus. Diabetes Care 2014;37(Suppl 1):S81–90.10.2337/dc14-S081Search in Google Scholar PubMed

3. Lippi G, Targher G. Glycated hemoglobin (HbA1c): old dogmas, a new perspective? Clin Chem Lab Med 2010;48:609–14.10.1515/CCLM.2010.144Search in Google Scholar PubMed

4. Plebani M, Lippi G. Point of care testing: evolving scenarios and innovative perspectives. Clin Chem Lab Med 2014;52: 309–11.10.1515/cclm-2013-0654Search in Google Scholar PubMed

5. Delatour V, Lalère B, Saint-Albin K, Peignaux M. Hattchouel JM, Dumont G, et al. Continuous improvement of medical test reliability using reference methods and matrix-corrected target values in proficiency testing schemes: application to glucose assay. Clin Chim Acta 2012;413:1872–8.10.1016/j.cca.2012.07.016Search in Google Scholar PubMed

6. Freckmann G, Schmid C, Pleus S, Baumstark A, Link M, Stolberg E, et al. System accuracy evaluation of systems for point-of-care testing of blood glucose: a comparison of a patient-use system with six professional-use systems. Clin Chem Lab Med 2014;52:1079–86.10.1515/cclm-2013-0976Search in Google Scholar PubMed

7. Chan H, Lunt H, Thompson H, Heenan HF, Frampton CM, Florkowski CM. Plasma glucose measurement in diabetes: impact and implications of variations in sample collection procedures with a focus on the first hour after sample collection. Clin Chem Lab Med 2014;52:1061–8.10.1515/cclm-2013-1059Search in Google Scholar PubMed

8. Fobker M. Stability of glucose in plasma with different anticoagulants. Clin Chem Lab Med 2014;52:1057–60.10.1515/cclm-2013-1049Search in Google Scholar PubMed

9. del Pino IG, Constanso I, Mourín LV, Safont CB, Vázquez PR. Citric/citrate buffer: an effective antiglycolytic agent. Clin Chem Lab Med 2013;51:1943–9.10.1515/cclm-2012-0735Search in Google Scholar PubMed

10. Gambino R, Bruns DE. Stabilization of glucose in blood samples: out with the old, in with the new. Clin Chem Lab Med 2013;51:1883–5.10.1515/cclm-2013-0341Search in Google Scholar PubMed

11. Szoke D, Valente C, Panteghini M. Better blood collection tubes for plasma glucose: ready for prime time? Clin Chem Lab Med 2014;52:e87–9.10.1515/cclm-2013-1006Search in Google Scholar PubMed

12. Lippi G, Salvagno GL, Montagnana M, Brocco G, Guidi GC. Influence of hemolysis on routine clinical chemistry testing. Clin Chem Lab Med 2006;44:311–6.10.1515/CCLM.2006.054Search in Google Scholar PubMed

13. Nielsen AA, Petersen PH, Green A, Christensen C, Christensen H, Brandslund I. Changing from glucose to HbA1c for diabetes diagnosis: predictive values of one test and importance of analytical bias and imprecision. Clin Chem Lab Med 2014;52:1069–77.10.1515/cclm-2013-0337Search in Google Scholar PubMed

14. Gillery P. A history of HbA1c through Clinical Chemistry and Laboratory Medicine. Clin Chem Lab Med 2013;51:65–74.10.1515/cclm-2012-0548Search in Google Scholar PubMed

Published Online: 2014-5-21
Published in Print: 2014-7-1

©2014 by Walter de Gruyter Berlin/Boston

Downloaded on 5.3.2024 from https://www.degruyter.com/document/doi/10.1515/cclm-2014-0443/html
Scroll to top button