Skip to content
Licensed Unlicensed Requires Authentication Published by De Gruyter December 5, 2011

Monitoring quality indicators in laboratory medicine does not automatically result in quality improvement

Laura Sciacovelli, Oswald Sonntag, Andrea Padoan, Carlo Federico Zambon, Paolo Carraro and Mario Plebani

Abstract

Background: Data on quality indicators (QIs) should be collected over time in order to identify and continuously monitor clinical laboratory performance and to improve patient safety by identifying and implementing effective interventions. The aim of the present study was to ascertain whether the utilization of a set of quality indicators over a 3-year period resulted in an improvement in the efficiency and effectiveness of an individual laboratory.

Methods: Over a 3-year time interval (2009–2011), a series of 38 QIs covering all stages of the total testing process (21 in the pre-analytic, nine in the analytic and eight in the post-analytic phase) was monitored.

Results: On the basis of their patterns, QIs have been grouped into the following categories: [1] seven QIs of the pre-analytical phase and three of the intra-analytical phase with a significant trend and a significant linearity demonstrating an improvement over time; [2] 10 QIs of the pre-analytical and two of the intra-analytical phase with a significant trend and a non-significant linearity demonstrating that changes were not constant; [3] two QIs of the pre-analytical and one of the intra-analytical phase with a non-significant trend and significant linearity showing neither improvement nor worsening; and [4] two QIs of the pre-analytical and three of the intra-analytical phase with a non-significant trend and non-significant linearity.

Conclusions: Data on a set of QIs collected over a 3-year time-frame demonstrate that processes and indicators under the control of the clinical laboratory had improved much more than processes requiring close co-operation between the laboratory and care teams.


Corresponding author: Mario Plebani, Department of Laboratory Medicine, University-Hospital, via Giustiniani, 2 35128 Padua, Italy Phone: +39 049 8212792, Fax: +39 049 663240

Received: 2011-10-24
Accepted: 2011-11-10
Published Online: 2011-12-5
Published in Print: 2012-03-01

©2012 by Walter de Gruyter Berlin Boston