Abstract

A real-time heparin monitor is required to optimize the dosage of heparin and its antidote, protamine sulfate, during extracorporeal circulation procedures. The gate effect of molecularly imprinted polymer (MIP) is a potential tool for the rapid and selective sensing of heparin. We here present a method to stabilize the measurement of heparin concentration in whole blood using an MIP-grafted electrode. An initiator of radical polymerization, the diethyldithiocarbamicbenzyl group, was introduced onto the surface of an indium-tin oxide (ITO) electrode. Heparin sodium, methacryloxethyltrimethoxysilane, and acrylamide were dissolved in water, and methylenebisacrylamide was dissolved in dimethylformamide. A mixture of the two solutions was introduced into the 50 μm gap between the surfaces of a quartz crystal plate and the treated ITO electrode. Ultraviolet light was irradiated onto the surface of the ITO to graft the copolymer of the monomers, then the ITO was washed with a 1 M sodium chloride aqueous solution to remove the heparin template and obtain the MIP-grafted electrode. Cyclic voltammetry was performed with the MIP-grafted electrode in physiological saline or bovine whole blood containing 0-8 units/ mL heparin and 5 mM ferrocyanide as a redox marker, and the relationship between the current intensity and the heparin concentration was analyzed. The current intensity decreased as the heparin concentration in either saline or whole blood increased, and the sensitivity of the electrode to heparin in blood was approximately 52% of its sensitivity to heparin in saline. The grafted-electrode was washed with a protease-containing detergent (Sterizyme® S, Maruishi Pharmaceutical) between measurements in blood. The heparin-sensitivity of the washed electrode in blood was 77% of that in saline. No sensitivity to chondroitin sulfate C was observed but sensitivity to low molecular weight heparin was demonstrated. We thus conclude that selective and stable sensing of heparin can be achieved using an electrode grafted with heparinimprinted polymer.

References

Korkmaz, M.E., Heparin and low molecular weight heparins in clinical cardiology In: Garg H.G., Limhardt, R.J., Hales, C.A. (Ed.), Chemistry and Biology of Heparan Sulfate, Elsevier, 2005, pp.637-672.10.1016/B978-008044859-6/50024-1Search in Google Scholar

Krishnaswamy, A., Kapadia, S.R., Percutaneous coronary intervention In: Griffin, B.P. (Ed.). Manual of Cardiovascular Medicine, 4th ed., Lippincott Williams & Wilkins, 2013, pp1041-1061.Search in Google Scholar

Krebs, C.R, Li, L., Wolberg, A.S., Oldenburg, A.L., A portable blood plasma clot micro-elastometry device based on resonant acoustic spectroscopy, Rev. Sci. Instrum. 2015, 86, No. 075005.Search in Google Scholar

Lesserson L.S., Gravlee L.S., Anticoagulation for cardiopulmonary bypass In: Gravee G.P., Davis R.F., Stammers A.F., Ungerleider R.M. (Eds.), Cardiopulmonary Bypass, 3rd ed., Lippincott Williams & Wilkins, Philadelphia, 2007 Li, L., Liang, Y., Liu Y., Designing of molecularly imprinted polymer-based potentiometric sensor for the determination of heparin, Anal. Biochem. 2013, 434, 242-246.Search in Google Scholar

Mang A., Pill J., Gretz, N., Kränzlin B., Buck H., Schoemaker M., Petrich W., Biocompatibility of an electrochemical sensor for continuous glucose monitoring in subcutaneous tissue, Diabetes Technol. Ther., 2005, 7, 163-73.10.1089/dia.2005.7.163Search in Google Scholar

Ohata T., Sawa Y., Ohtake S., Nishimura M., Chan C.-J., Suzuki K., Matsuda H. Clinical role of blood heparin level monitoring during open heart surgery, Jpn. J. Thorac. and Cardiovasc. Surg. 1999, 47, 600–606.Search in Google Scholar

Sekine, S., Watanabe, Y., Yoshimi, Y. Hattori K., Sakai K. Influence of solventsonchiral discriminativegate effectofmolecularly imprinted poly(ethyleneglycol dimethacrylatecomethacrylic acid), Sens. Actuators, B, 2007, 127, 512–517.10.1016/j.snb.2007.05.008Search in Google Scholar

Yoshimi Y., Sato K., Oshima, M., Piletska E., Application of the ‚gate effect‘ of a molecularly imprinted polymer grafted on an electrode for the real-time sensing of heparin in blood, Analyst, 2013, 138, 5121-5128.10.1039/c3an00909bSearch in Google Scholar

Yoshimi Y., Ohdaira R., Iiyama C., Sakai K., “Gate effect” of thin layer of molecularly-imprinted poly (methacrylic acid-co-ethyleneglycol dimethacrylate), Sens. Actuators, B, 2001, 73, 49–53.10.1016/S0925-4005(00)00671-7Search in Google Scholar

Yoshimi Y., Ishii N., Improved gate effect enantioselectivity of phenylalanine- imprinted polymers in water by blending crosslinkers, Anal. Chim. Acta, 2015, 862, 77-85.10.1016/j.aca.2015.01.001Search in Google Scholar PubMed

Yoshimi Y., Narimatsu A., Nakayama K., Sekine S., Hattori K.., Sakai K., Development of an enzyme-free glucose sensor using the gate effect of a molecularly imprinted polymer, J. Artif. Organs, 2009, 12, 264–270. 10.1007/s10047-009-0473-4Search in Google Scholar PubMed

Received: 2015-8-23
Accepted: 2016-1-14
Published Online: 2016-3-15

© 2016 Yasuo Yoshimi et al.

This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.

Downloaded on 21.2.2024 from https://www.degruyter.com/document/doi/10.1515/molim-2016-0002/html
Scroll to top button