Accessible Requires Authentication Published by De Gruyter April 5, 2013

Heat transfer to the building structures of the Ignalina NPP accident localisation system

Wärmeübertragung auf die Baustrukturen des Confinements des KKW Ignalina
E. Babilas, S. Rimkevičius and E. Urbonavičius
From the journal Kerntechnik

Abstract

The performed thermal-hydraulic analysis of the Accident Localisation System (ALS) has shown, that in the case of a Maximum Design Basis Accident (MDBA), in the long term, a significant amount of energy (∼40%) is transferred to the building structures. Therefore, special attention should be paid to the correct simulation of the building structures and heat transfer processes. Free convection, forced convection, condensation and conductivity are the phenomena, which are connected with the heat transfer to the building structures and should be investigated. In this paper, the heat transfer models available in the COCOSYS code, which is applied for the analysis, are discussed. The influence of the heat transfer models on the behaviour of thermal-hydraulic parameters in ALS compartments during MDBA is investigated.

Kurzfassung

Die durchgeführte thermohydraulische Analyse des Confinements hat gezeigt, dass im Verlauf eines maximalen Auslegungsstörfalls (DBA) ein bedeutender Energiebetrag (∼40%) auf die Baustrukturen übertragen wird. Deshalb sollte die Modellierung von Baustrukturen und von Wärmeübertragungsprozessen besonders sorgfältig betrachtet werden. Natur- und Zwangskonvektion, Kondensation und Leitfähigkeit sind die Phänomene, die mit der Wärmeübertragung auf die Baustrukturen verbunden sind und untersucht werden sollten. Im vorliegenden Beitrag werden die Wärmeübertragungsmodelle des COCOSYS-Codes diskutiert. Der Einfluss der Wärmeübertragungsmodelle auf das Verhalten von thermohydraulischen Parametern in Confinement-Räumen während eines Auslegungsstörfalls (DBA) wird untersucht.

References

1 Almenas, K.; Kaliatka, A.; Rimkevičius, S.; Sehgal, B. R.; Učpuras, E.; Žvinys, E.: Evaluation of the RBMK-1500 Accident Confinement System. Report of Ignalina Safety Analysis Group (LEI) and Department of Nuclear Engineering (University of Maryland) MD-NUME-96-09 Search in Google Scholar

2 Almenas, K.; Cesna, B.; Kaliatka, A.; Rimkevičius, S.; Sehgal, B. R.; Učpuras, E.; Žvinys, E.: Thermal-hydraulic evaluation of the RBMK-500 accident confinement system using CONTAIN 11AF. Nuclear engineering and design191 (1999) 83 10.1016/S0029-5493(99)00055-2 Search in Google Scholar

3 Almenas, K.; Kaliatka, A.; Učpuras, E.: Ignalina RBMK-1500, A source book, Lithuania Energy Institute (1998) Search in Google Scholar

4 Babilas, E.; Rimkevičius, S.; Urbonavičius, E.: Wlijanie modelirowanija ctroitelnych konstrukzij na resultaty termohidravlitscheskogo rastschjeta pomeschtschenij SLA Ignalinskoj AES, Energetika, Vilnius (2002) Search in Google Scholar

5 VDI Wärmeatlas, 5. Auflage1988, Blätter Gb VDI-Verlag, Düsseldorf (1988) Search in Google Scholar

6 Gimbutis, G.; Kajutis, K.; Krukonis, V.; Pranckũnas, A.; Švenčianas, P.: Šiluminė technika, Vilnius „Mokslas“ 1993 Search in Google Scholar

7 Grigull, U.: Die Grundgesetze der Wärmeübertragung. Springer-Verlag (1963) Search in Google Scholar

Received: 2009-8-4
Published Online: 2013-04-05
Published in Print: 2010-03-01

© 2010, Carl Hanser Verlag, München