Abstract

In the context of two reactor decommissioning projects, radioactive slurry from concrete cutting was collected in the retention pond (RHB) at the Paul Scherrer Institute, along with radioactive drain outlets. Additionally, there are active residues from former operations. The task was to determine the nuclide vector of the radioactive slurry before final disposal. Due to the slurry from neutron-activated concrete, activation products, like 55Fe, 60Co, 63Ni, 133Ba, 152Eu, 154Eu and 155Eu can be expected. Accumulated drain outlets from laboratories, where work with radioactive substances is being done, were expected to contain 22Na, 60Co, 134Cs, 137Cs, 133Ba, 152Eu, 154Eu, 155Eu, 241Am, 239/240Pu, 241Pu, 244Cm, 234U, 235U, 238U, 230Th, 232Th and 90Sr. For further clarification, 3H and 14C in the water and in the organic phase had to be measured as well. This work gives an overview about the slurry dissolution techniques, the radiochemical separation methods and activity concentrations of the nuclide vector. Further processing of the slurry is also discussed.

Kurzfassung

Im Rahmen zweier Reaktor-Rückbauprojekte floss deren Schneidschlamm in das Rückhaltebecken Wald (RHB) am Paul Scherrer Institut, nebst anderen radioaktiven Wasserzuflüssen. In diesem Rückhaltebecken befinden sich noch radioaktive Rückstände aus früheren Tätigkeiten. Die Aufgabe war es nun, den Nuklidvektor des Schlammes zu bestimmen, bevor er fachgerecht entsorgt werden kann. Durch den Schlamm von neutronen-aktiviertem Beton können Aktivierungsprodukte wie 55Fe, 60Co, 63Ni, 133Ba, 152Eu, 154Eu und 155Eu erwartet werden. Von akkumulierten Abwasser aus Labors, in denen mit radioaktiven Substanzen gearbeitet wird, können zudem die Nuklide 22Na, 60Co, 134Cs, 137Cs, 133Ba, 152Eu, 154Eu, 155Eu, 241Am, 239/240Pu, 241Pu, 244Cm, 234U, 235U, 238U, 230Th, 232Th und 90Sr erwartet werden. Für die Abklärung der weiteren Schlammbehandlung vor der Entsorgung mussten auch 3H und 14C im überstehenden Wasser und im organischen Anteil bestimmt werden. Diese Arbeit gibt einen Überblick über die verwendeten Schlammaufschlussmethoden, radiochemischen Trennverfahren und Aktivitätskonzentrationen des Nuklidvektors. Des Weiteren wird die Behandlung des Schlammes diskutiert.

References

1 Croudace, I.; Warwick, P.; Taylor, R.; Dee, S.: Rapid procedure for plutonium and uranium determination in soils using a borate fusion followed by ion-exchange and extraction chromatography. Analytica Chimica Acta371 (1998) 21722510.1016/S0003-2670(98)00353-5 Search in Google Scholar

2 Warwick, P. E.; Croudace, I. W.; Oh, J.-S.: Radiochemical determination of 241Am and Pu() in environmental materials. Analytical Chemistry73 (2001) 3410341610.1021/ac001510e Search in Google Scholar

3 Bock, R.: Handbuch der analytisch-chemischen Aufschlussmethoden, Wiley, Weinheim, p. 327, 2001 Search in Google Scholar

4 Jäggi, M.; Eikenberg, J.: Separation of 90Sr from radioactive waste matrices – Microwave versus fusion decomposition. Applied Radiation and Isotopes67 (2009) 76576910.1016/j.apradiso.2009.01.032 Search in Google Scholar

5 Jäggi, M.; Rüthi, M.; Eikenberg, J.: Method for 55Fe and 63Ni determination by LSC in radioactive waste. In: Eikenberg, J., Jäggi, M., Beer, H., Baehrle, H. (Eds.). Liquid Scintillation Spectrometry p. 3139, 2008 Search in Google Scholar

6 Bajo, S.; Eikenberg, J.: Electrodeposition of actinides for alpha-spectrometry. Journal of Radioanalytical and Nuclear Chemistry242 (1999) 74575110.1007/BF02347389 Search in Google Scholar

7 Jäggi, M.; Röllin, S.; Corcho AlvaradoJ.A.; Eikenberg, J.: Determination of 241Pu in nuclear waste slurries: A comparative study using LSC and ICP-MS, 70, p. 360364, 2012 Search in Google Scholar

8 Eikenberg, J.; Beer, H.; Rüthi, M.; Zumsteg, I.; Vetter, A.: Precise determination of 89Sr und 90Sr 90Y in various matrices: The LSC three window approach. In: Chalupnik, S., Schönhofer, F., Noakes, J. (Eds.). LSC 2005 Advances in Liquid Scintillation Spectrometry, p. 237249, 2005 Search in Google Scholar

Received: 2012-1-13
Published Online: 2013-05-13
Published in Print: 2012-06-01

© 2012, Carl Hanser Verlag, München