Issues

Beobachtung des Patientenzustands bei Herzoperationen (Observing Patient Status during Cardiac Surgery)

E. Naujokat / Uwe Kiencke
Published Online: 2009-09-25 | DOI: https://doi.org/10.1524/auto.2002.50.5.204

Die meisten Eingriffe in der Herzchirurgie erfordern ein stillgelegtes, blutleeres Herz und werden daher unter extrakorporaler Zirkulation (EKZ), das heißt mit Hilfe einer Herz-Lungen-Maschine (HLM) durchgeführt. Während der EKZ sind viele wichtige Kreislaufgrößen unbekannt, da für Messsonden unzugänglich, wie zum Beispiel die Perfusion von Gehirn und Nieren, oder werden nur in größeren Zeitabständen erfasst, wie zum Beispiel die Messgrößen der Blutanalyse. In diesem Beitrag wird ein Beobachtersystem vorgestellt, das derartige Patientenparameter kontinuierlich intraoperativ schätzt. Dadurch wird die Informationsbasis für die Entscheidungen des Kardiotechnikers zur Regelung der HLM erweitert, und somit wird dazu beigetragen, postoperative Schäden für den Patienten zu vermeiden.

Most interventions in cardiac surgery require a resting, bloodless heart and are executed under extracorporeal circulation (ECC), i. e. using a heart-lung machine. During ECC many important patient parameters cannot be measured, such as brain or kidney perfusion, or are only measured in greater intervals of time, such as blood gases or pH. A state-observer estimating these parameters continuously and intra-operatively will improve the information basis of the perfusionist for controlling the heart-lung machine and contribute to the safety of this operating technique.

About the article

Published Online: 2009-09-25

Published in Print: 2002-05-01


Citation Information: at - Automatisierungstechnik Methoden und Anwendungen der Steuerungs-, Regelungs- und Informationstechnik, Volume 50, Issue 5/2002, Pages 204–, ISSN (Print) 0178-2312, DOI: https://doi.org/10.1524/auto.2002.50.5.204.

Export Citation

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
G. Meyrowitz, T. Schmidt, E. Naujokat, J. Albers, U. Kiencke, C. F. Vahl, and S. Hagl
Biomedizinische Technik/Biomedical Engineering, 2002, Volume 47, Number s1b, Page 915
[2]
E. Naujokat, J. Barrho, G. Meyrowitz, C. F. Vahl, and U. Kiencke
Biomedizinische Technik/Biomedical Engineering, 2002, Volume 47, Number s1a, Page 235
[3]
Anja Brunberg, Stefanie Heinke, Jan Spillner, Rüdiger Autschbach, Dirk Abel, and Steffen Leonhardt
Biomedizinische Technik/Biomedical Engineering, 2009, Volume 54, Number 5, Page 233