Jump to ContentJump to Main Navigation
Show Summary Details
More options …

at - Automatisierungstechnik

Methoden und Anwendungen der Steuerungs-, Regelungs- und Informationstechnik

[AT - Automation Technology: Methods and Applications of Control, Regulation, and Information Technology
]

Editor-in-Chief: Jumar, Ulrich


IMPACT FACTOR 2017: 0.503

CiteScore 2017: 0.47

SCImago Journal Rank (SJR) 2017: 0.212
Source Normalized Impact per Paper (SNIP) 2017: 0.546

Online
ISSN
2196-677X
See all formats and pricing
More options …
Volume 58, Issue 5

Issues

Automatisierung und Fehlerdiagnose bei der extrakorporalen Membranoxygenierung

Marian Walter / André Stollenwerk / Tobias Wartzek / Jutta Arens / Rüdiger Kopp
  • 4 Universitätsklinikum Aachen, Fachübergreifende Klinik für operative Intensivmed, Aachen
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Steffen Leonhardt
Published Online: 2010-05-10 | DOI: https://doi.org/10.1524/auto.2010.0838

Zusammenfassung

Die Extrakorporale Membranoxygenierung ist eine der letzten Therapieoptionen für schwere Fälle eines akuten Lungenversagens. Hierzu wird Blut in einem externen Kreislauf ähnlich einer Herz-Lungen-Maschine durch einen Oxygenator gepumpt. In diesem findet ein zusätzlicher Gasaustausch statt. Im Gegensatz zum Einsatz im Operationssaal wird die länger andauernde Therapie auf der Intensivstation in der Regel nicht kontinuierlich durch einen Kardiotechniker überwacht. Die in diesem Beitrag vorgestellten Konzepte für Automatisierung und Fehlerdiagnose sind ein wichtiger Schritt hin zu einem sicheren und zuverlässigen teil-autonomen Betrieb eines Systems, das sich den individuellen Bedürfnissen des Patienten kontinuierlich anpasst.

Abstract

In severe cases of acute respiratory distress syndrome, extracorporeal membrane oxygenation is one of the ultima ratio therapy options. Using an external circuit similar to a conventional cardio-pulmonary bypass system, blood is pumped through an oxygenator, where additional gas exchange can be provided. However, continuous supervision and control of the machine by a perfusionist can not be maintained in an intensive care unit. The presented control concepts and fault diagnosis schemes point the way to a long-term semi-autonomous safe operation which adapts to patient demand.

Keywords: Regelung; Medizintechnik; ECMO; Sicherheit; Fehlerdiagnose

About the article

* Correspondence address: RWTH Aachen, Phillips Lehrstuhl für Medizinische Informationste, Pauwelsstr. 20, Helmholtz Institut für Biomedizinische Technik, 52074 Aachen, Deutschland,


Published Online: 2010-05-10

Published in Print: 2010-05-01


Citation Information: at - Automatisierungstechnik Methoden und Anwendungen der Steuerungs-, Regelungs- und Informationstechnik, Volume 58, Issue 5, Pages 277–285, ISSN (Print) 0178-2312, DOI: https://doi.org/10.1524/auto.2010.0838.

Export Citation

© by Oldenbourg Wissenschaftsverlag, München, Germany.Get Permission

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
Hany Hazfiza Manap, Ahmad Khairi Abdul Wahab, and Fathiah Mohamed Zuki
IOP Conference Series: Materials Science and Engineering, 2017, Volume 210, Page 012003

Comments (0)

Please log in or register to comment.
Log in