Jump to ContentJump to Main Navigation
Show Summary Details
More options …

Bio-Algorithms and Med-Systems

Editor-in-Chief: Roterman-Konieczna , Irena

4 Issues per year

Online
ISSN
1896-530X
See all formats and pricing
More options …

List-mode reconstruction in 2D strip PET

Piotr Białas / Jakub Kowal / Adam Strzelecki / Tomasz Bednarski / Eryk Czerwiński / Krzysztof Giergiel / Łukasz Kapłon
  • Institute of Physics, Jagiellonian University, 30-059 Cracow, Poland
  • Faculty of Chemistry, Jagiellonian University, 30-060 Cracow, Poland
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Andrzej Kochanowski / Grzegorz Korcyl / Paweł Kowalski / Tomasz Kozik / Wojciech Krzemień / Marcin Molenda / Ines Moskal / Paweł Moskal / Szymon Niedźwiecki / Marek Pałka / Monika Pawlik / Lech Raczyński / Zbigniew Rudy / Piotr Salabura / Neha G. Sharma / Michał Silarski / Artur Słomski / Jerzy Smyrski / Konrad Szymański / Wojciech Wiślicki / Piotr Witkowski / Marcin Zieliński / Natalia Zoń
Published Online: 2014-03-03 | DOI: https://doi.org/10.1515/bams-2013-0111

Abstract

Using a theory of list-mode maximum likelihood expectation-maximization (MLEM) algorithm, in this contribution, we present a derivation of the system response kernel for a novel positron emission tomography (PET) detector based on plastic scintillators.

Keywords: image reconstruction; MLEM; Monte Carlo simulation

References

  • 1.

    Shepp LA, Vardi Y. Maximum likelihood reconstruction in positron emission tomography. IEEE Trans Med Imaging 1982;MI-1:113–22.CrossrefGoogle Scholar

  • 2.

    Shepp LA, Vardi Y, Kaufman L. A statistical model for positron emission tomography. J Am Stat Assoc 1985;80:8–20.Google Scholar

  • 3.

    Moskal P, Salabura P, Silarski M, Smyrski J, Zdebik J, Zieliński M. Novel detector systems for the positron emission tomography. Bio-Algorithms Med-Syst 2011;7:73.Google Scholar

  • 4.

    Moskal P, Bednarski T, Białas P, Ciszewska M, Czerwiński E, Heczko A, et al. Strip-PET: a novel detector concept for the TOF-PET scanner. Nucl Med Rev C 2012;15:68–9.Google Scholar

  • 5.

    Moskal P, Bednarski T, Białas P, Ciszewska M, Czerwiński E, Heczko A, et al. TOF-PET detector concept based on organic scintillators. Nucl Med Rev C 2012;15:81–4.Google Scholar

  • 6.

    Parra L, Berret HH. List-mode likelihood EM algorithm and noise estimation demonstrated on 2D-PET. IEEE Trans Med Imaging 1998;17:228–35.CrossrefGoogle Scholar

  • 7.

    Berret HH, White T, Parra L. List-mode likelihood. J Opt Soc Am A Opt Image Sci Vis 1997;14:2914–23.CrossrefGoogle Scholar

About the article

Corresponding author: Adam Strzelecki, Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, Reymonta 4, Room 05A, 30-059 Cracow, Poland, E-mail:


Received: 2013-10-29

Accepted: 2014-01-07

Published Online: 2014-03-03

Published in Print: 2014-03-31


Citation Information: Bio-Algorithms and Med-Systems, Volume 10, Issue 1, Pages 9–12, ISSN (Online) 1896-530X, ISSN (Print) 1895-9091, DOI: https://doi.org/10.1515/bams-2013-0111.

Export Citation

©2014 by Walter de Gruyter Berlin/Boston. Copyright Clearance Center

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
W. Krzemień, A. Gajos, A. Gruntowski, K. Stola, D. Trybek, T. Bednarski, P. Białas, E. Czerwiński, D. Kamińska, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, E. Kubicz, P. Moskal, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, P. Salabura, N.G. Sharma, M. Silarski, A. Słomski, J. Smyrski, A. Strzelecki, A. Wieczorek, W. Wiślicki, M. Zieliński, and N. Zoń
Acta Physica Polonica A, 2015, Volume 127, Number 5, Page 1491

Comments (0)

Please log in or register to comment.
Log in