Jump to ContentJump to Main Navigation
Show Summary Details
More options …

Biomedical Engineering / Biomedizinische Technik

Editor-in-Chief: Dössel, Olaf

Editorial Board Member: Augat, Peter / Haueisen, Jens / Jockenhoevel, Stefan / Lenarz, Thomas / Leonhardt, Steffen / Plank, Gernot / Radermacher, Klaus M. / Schkommodau, Erik / Stieglitz, Thomas / Boenick, Ulrich / Jaramaz, Branislav / Kraft, Marc / Lenthe, Harry / Lo, Benny / Mainardi, Luca / Micera, Silvestro / Penzel, Thomas / Robitzki, Andrea A. / Schaeffter, Tobias / Snedeker, Jess G. / Sörnmo, Leif / Sugano, Nobuhiko / Werner, Jürgen /

6 Issues per year


IMPACT FACTOR 2016: 0.915
5-year IMPACT FACTOR: 1.263

Online
ISSN
1862-278X
See all formats and pricing
More options …
Volume 56, Issue 1 (Feb 2011)

Issues

Volume 57 (2012)

Amplifier design for EMG recording from stimulation electrodes during functional electrical stimulation leg cycling ergometry

Raafat Shalaby / Thomas Schauer / Wolfgang Liedecke / Jörg Raisch
  • Control Systems Group, Technische Universität Berlin, Berlin, Germany
  • Systems and Control Theory Group, Max Planck Institute for Dynamics of Complex Technical Systems, Magdeburg, Germany
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
Published Online: 2010-12-17 | DOI: https://doi.org/10.1515/bmt.2010.055

Abstract

Functional electrical stimulation leg cycle ergometry (FES-LCE), which is often used as exercise for people with spinal cord injury (SCI), has recently been applied in the motor rehabilitation of stroke patients. Recently completed studies show controversial results, but with a tendency to positive training effects. Current technology is identical to that used in FES-LCE for SCI, whereas the pathology of stroke differs strongly. Most stroke patients with hemiparesis are able to drive an ergometer independently. Depending on the degree of spasticity, the paretic leg will partially support or hinder movements. Electrical stimulation increases muscle force and endurance and both are prerequisites for restoring gait. However, the effect of FES-LCE on improving impaired motor coordination is unclear. To measure motor coordination during FES-LCE, an EMG-amplifier design has been investigated which suppresses stimulation artifacts and allows detection of volitional or reflex induced muscle activity. Direct measurement of EMG from stimulation electrodes between stimulation pulses is an important asset of this amplifier. Photo-MOS switches in front of the preamplifier are utilized to achieve this. The technology presented here can be used to monitor the effects of FES-LCE to adapt the stimulation strategy or to realize EMG-biofeedback training.

Keywords: artifact suppression; cycling; electromyography; functional electrical stimulation; stimulation electrodes; stroke rehabilitation

About the article

Corresponding author: Thomas Schauer, Control Systems Group, Technische Universität Berlin, Einsteinufer 17, 10587 Berlin, Germany


Received: 2010-03-04

Accepted: 2010-11-03

Published Online: 2010-12-17

Published Online: 2010-12-17

Published in Print: 2011-02-01


Citation Information: Biomedizinische Technik/Biomedical Engineering, ISSN (Online) 1862-278X, ISSN (Print) 0013-5585, DOI: https://doi.org/10.1515/bmt.2010.055.

Export Citation

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
C. Klauer, S. Ferrante, E. Ambrosini, U. Shiri, F. Dähne, I. Schmehl, A. Pedrocchi, and T. Schauer
Medical Engineering & Physics, 2016, Volume 38, Number 11, Page 1232
[2]
Emilia Ambrosini, Simona Ferrante, Thomas Schauer, Christian Klauer, Marina Gaffuri, Giancarlo Ferrigno, and Alessandra Pedrocchi
Journal of Electromyography and Kinesiology, 2014, Volume 24, Number 2, Page 307

Comments (0)

Please log in or register to comment.
Log in